Why the study?
Traditional transvenous ICD placement in low-weight children is difficult due to small vessel size, elevated risks of lead failure, growth, and anatomic constraints, creating a need for alternative solutions.
Is the subcutaneous finger cardioverter defibrillator safe and feasible in low-weight pediatric patients?
Is the subcutaneous finger cardioverter defibrillator safe and feasible in low-weight pediatric patients?
The subcutaneous finger cardioverter defibrillator appears to be a safe and feasible alternative to transvenous ICDs in low-weight children, preserving the vascular system.
Answers are grounded in this paper and cite their sources.
May offer alternative ICD placement in low-weight children with vessel constraints; hypothesis-generating, requiring prospective validation.
Placement of traditional transvenous implantable cardioverter defibrillator (ICD) system in low-weight children is often difficult because of their vessel size, the elevated risk of lead malfunction and failure, children's growth and various anatomic constraints, creating the need for alternative solutions. Subcutaneous array leads combined with an abdominally placed ICD device can minimize the surgical approach. In this case series, we analyse the data behind indications for subcutaneous finger cardioverter defibrillator (SFCD) and discuss the preliminary clinical experience in low-weight children. We considered 4 consecutive children (mean age 3.9 years, range 3-5.5 years, mean body weight 17.6 Kg, range 14-23 Kg) who underwent SFCD implant from April 2016 to August 2020. All patients showed a good compliance to the device system with no complications (infections or skin erosions). No patients experienced in the observation period (mean time 44.5±21.5 months) sustained ventricular arrhythmias requiring shocks. No inappropriate shocks released by the device occurred. No significant changes were observed in LET (lowest energy tested) performed around 24 months of follow-up. All patients showed a good compliance and stable atrio-ventricular sensing and pacing thresholds. In smaller children in whom a transvenous approach is not feasible or not possible for anatomic reasons, the SFCD appears to be a safe method to prevent SCD with little surgical trauma and preservation of an intact vascular system, providing an adequate bridge to transvenous ICD or subcutaneous ICD implant late in the life.
No takes yet. Share an insight, caveat, or question.
Sarubbi et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: