Why the study?
Is ICD implantation without epicardial patches or transvenous high-energy leads feasible and effective in pediatric and congenital heart disease patients?
Is ICD implantation without epicardial patches or transvenous high-energy leads feasible and effective in pediatric and congenital heart disease patients?
Novel ICD configurations without epicardial patches or transvenous high-energy leads are feasible in pediatric and congenital heart disease patients, though system revisions and inappropriate shocks are notable.
Answers are grounded in this paper and cite their sources.
Supports novel ICD configurations in pediatric CHD; leaves open long-term safety and efficacy in larger cohorts.
Introduction: In pediatric and congenital heart disease patients, transvenous ICD implantation may be limited secondary to patient size, venous, or cardiac anatomy. Epicardial patches require a thoracotomy, and may lead to a restrictive pericardial process. Because of these issues, we have explored novel ICD configurations. Methods: Retrospective review at 10 centers implanting ICDs without a transvenous shocking coil or epicardial patches. Results: Twenty‐two patients underwent implant at a mean age of 8.9 years (range: 0.3–43.5), with a mean weight of 25.5 kg (range: 5.2–70). Diagnoses included complex CHD, intracardiac tumors, cardiomyopathy, idiopathic VT, LV noncompaction, and long QT syndrome. Three configurations were used: subcutaneous array, a transvenous design ICD lead placed on the epicardium, or a transvenous design ICD lead placed subcutaneously. Difficulties were found at implant in 8 patients: 4 had difficulty inducing VT/VF, and 4 had high DFTs. Over a mean follow‐up of 2.2 years (range: 0.2–10.5), 7 patients had appropriate shocks. Inappropriate shocks occurred in 4 patients. System revisions were required in 7 patients: 2 generator changes (in 1 patient), 3 pace‐sense lead replacement, 1 additional subcutaneous coil placement due to increased DFT, 1 upgrade to a transvenous system, and 1 revision to epicardial patch system. Conclusions: ICD implantation can be performed without epicardial patches or transvenous high‐energy leads in this population, using individualized techniques. This will allow ICD use in patients who have intracardiac shunting or are deemed too small for transvenous ICD leads. The long‐term outcome and possible complications are as yet unknown in this population, and they should be monitored closely with follow‐up DFTs.
No takes yet. Share an insight, caveat, or question.
Stephenson et al. (2006) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: