Answers are grounded in this paper and cite their sources.
Series elastic actuators are increasingly adopted in wearable robots, due to superior sensing and actuating capabilities provided by the added internal compliance. However, when evaluating their performance in benchtop setups, the dynamics of the physical human–robot interface (i.e., external compliance) are usually overlooked despite it causing energy dissipation and delays in power transmission. This work closes the gap by emulating in a test bench the physical human–robot interaction dynamics and validating actuator performance against commonly used performance indices, including torque bandwidth, torque tracking, and transparency. The results show a significant impact of the interaction dynamics on the actuator performance. When interface dynamics is present, decreasing the actuator (internal) compliance has little to no effect on its bandwidth. When delivering a walking torque, decreasing internal (actuator) and external (interface) compliance has the same decreasing effect on the motor’s peak electrical power in the hip joint. Conversely, the motor peak electrical power decreases with an increase in internal (actuator) compliance but increases with an increase in external (interface) compliance in the knee joint. As such, this work demonstrates the importance of including interaction dynamics as a norm in designing and evaluating actuation units in wearable robots.
No takes yet. Share an insight, caveat, or question.
Sun et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: