Why the study?
Bioprosthetic valve durability is limited by structural valve deterioration from calcification, and there was no published clinical experience regarding the implantation of the novel Inspiris Resilia Aortic Valve in Africa.
This case report demonstrates the successful first implantation and favorable 1-year follow-up of the Inspiris Resilia Aortic Tissue Valve in Africa.
Answers are grounded in this paper and cite their sources.
May extend options for young patients in Africa; leaves open long-term clinical durability data.
The durability of artificial bioprosthestic or tissue heart valves is limited by structural valve deterioration (SVD) due to long-term calcification especially in young patients and in Africa. A novel bioprosthestic valve, the Resilia Inspiris Aortic Tissue Valve has been developed which, in preclinical studies, has shown reduced calcification thus improving durability. The Inspiris Resilia Aortic Valve is a stented tri-leaflet valve made from bovine pericardial tissue. The tissue is created by treating bovine pericardial tissue with Edwards Integrity Preservation. It incorporates a stable capping anticalcification process, which blocks residual aldehyde groups known to bind with calcium. Tissue preservation with glycerol allows the valve to be stored without a traditional liquid-based solution, such as glutaraldehyde. Therefore, the valve is stored under dry packaging conditions and consequently does not require rinsing prior to implantation. The novel tissue preservation technology significantly improves hemodynamic and anticalcification properties compared with the standard artificial bioprosthestic aortic valve, the Perimount tissue valve. The experience of the implantation of this valve in Africa is limited for there seems to be no published experience of the behaviour of the implantation of this special long lasting bioprosthestic valve in Africa and therefore the purpose of this paper is to share our initial experience of the first successful implantation of this Inspiris Resilia Aortic Valve™ in Ghana, Africa. The implantation was done in a 57-year-old patient who presented with symptomatic moderate to severe aortic valve regurgitation with adequate left ventricular systolic function. He has been followed-up for a year now with well-healed wounds and a transthoracic echocardiography revealing a well-seated valve with no regurgitant flow or paravalvular leak. This is the first report describing the use of the new Inspiris Resilia Aortic valve which has increased durability and does not require anticoagulation in Africa as far as we know.
No takes yet. Share an insight, caveat, or question.
Okyere et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: