Key result
Semi-quantitative first-pass perfusion CMR shows superior reproducibility compared to fully quantitative analysis.
Why the study?
Reproducibility data for first-pass CMR perfusion estimates are sparse, yet such data are needed to monitor the response to therapies that affect myocardial blood flow.
What is the intraobserver, interobserver, and interstudy reproducibility of semi-quantitative and fully quantitative myocardial blood flow estimation from first-pass perfusion CMR at rest and during adenosine-induced hyperaemia?
What is the intraobserver, interobserver, and interstudy reproducibility of semi-quantitative and fully quantitative myocardial blood flow estimation from first-pass perfusion CMR at rest and during adenosine-induced hyperaemia?
First-pass perfusion CMR provides reproducible global myocardial perfusion estimates at rest and during adenosine stress, with semi-quantitative analysis showing superior reproducibility compared to fully quantitative Fermi deconvolution.
Answers are grounded in this paper and cite their sources.
Supports semi-quantitative first-pass perfusion CMR in research; leaves open standardization of quantitative methods before clinical use.
Methods 11 volunteers (6 males, mean age 33 ± 7 years) underwent CMR perfusion on 2 separate days (mean interstudy delay = 84 ± 111 days, median delay = 7 days) on a 1.5 T Philips Intera system during adenosine-induced hyperaemia (140 mcg/kg/min, 0.05 mmol/kg Gd-DTPA) and rest. A pulse sequence optimised for acquisition of a single midventricular slice at systole was used (saturation recovery segmented gradient echo, 2 × SENSE TR/TE/flip 2.7 ms/1.0/ 15°, typical FOV 380 × 380 mm, matrix 160 × 160, slice thickness 10 mm, preparation pulse delay 150 ms, shot duration 130 ms). Endoand epicardial contours were drawn. "Semi"-quantitative analysis calculated maximal upslopes of myocardial signal intensity of the entire slice, normalised to the LV blood-pool (Myocardial perfusion index, MPI) using MASS 6.0 (Medis, Leiden, The Netherlands). The myocardial perfusion reserve index (MPRI) was calculated as the ratio of hyperaemic over rest MPI.
No takes yet. Share an insight, caveat, or question.
Larghat et al. (2010) studied Healthy volunteers undergoing myocardial perfusion assessment (n=11). First-pass perfusion cardiovascular magnetic resonance (CMR) during adenosine-induced hyperaemia and at rest vs. Semi-quantitative analysis (maximal upslopes/MPI) vs fully quantitative analysis (Fermi function deconvolution); intraobserver, interobserver, and interstudy comparisons was evaluated on Reproducibility of semi-quantitative (myocardial perfusion index [MPI] and myocardial perfusion reserve index [MPRI]) and quantitative (absolute myocardial blood flow in ml/g/min) CMR perfusion estimates. First-pass perfusion CMR demonstrated good global reproducibility at rest and during hyperaemia, with semi-quantitative measurements being generally more reproducible than fully quantitative analysis.