Glucagon is a 29-amino acid polypeptide, secreted from the pancreatic α-cells and probably, to a lesser extent, extra-pancreatic tissues. Following its discovery in 1923 as an element of pancreatic extract that induced hyperglycaemia, glucagon has been established as an important hormone that orchestrates glucose, lipid and amino acid metabolism, as well as energy intake and expenditure. Accordingly, plasma glucagon has been measured in numerous studies to elucidate the pathophysiological features of metabolic disorders and/or mechanism(s) underlying the effects of therapeutic interventions. Because of the low concentration of glucagon in the peripheral circulation and the potential for cross-reactivity of glucagon-detecting antibodies against other proglucagon-derived products (e.g. oxyntomodulin, glicentin), accurate measurement of glucagon has been challenging. Thus, the possibility that commercial kits may fail to measure glucagon precisely represents a major concern for the interpretation of glucagon data in clinical studies. Since the development of the first radioimmunoassay (RIA) for glucagon in 1959, several RIAs that detect the C-terminus of glucagon (e.g. the Millipore RIA kit) were found to be of sufficiently high sensitivity and specificity for the measurement of plasma glucagon. More recently, sandwich ELISA kits that detect both the Nand C-terminus of glucagon (e.g. the Mercodia ELISA kit) have become available, and yield highly specific detection of intact glucagon. However, RIAs continue to be used widely, because their cost is substantially less. In our routine use of RIA for glucagon analysis, we began seeing unexpected plasma glucagon responses to oral and enteral glucose loads in both healthy humans and patients with type 2 diabetes, which differed markedly from responses seen in similar subjects in earlier studies. Closer scrutiny revealed that the onset of these observations coincided with the introduction of a new batch of antibody in the Millipore glucagon RIA kit (GL-32K) in mid-2019. To clarify this further, we compared plasma concentrations of glucagon measured using the Millipore RIA kits manufactured before and after the change of antibody with those measured by the Mercodia ELISA kit (10-1271-01), in two separate studies. In study 1, plasma samples were obtained from 10 healthy individuals, who received an intraduodenal infusion of glucose (30 g glucose dissolved in water to a final volume of 120 ml) over 60 minutes (i.e. 2 kcal/min) via a transnasal catheter. As shown in Figure 1A–C, plasma glucagon, measured by the old Millipore RIA kit and the Mercodia ELISA kit, while differing at baseline, exhibited a similar decrease during intraduodenal glucose infusion (P < .001 for each), with a strong correlation between the integrated glucagon response relative to baseline (calculated as the area under the curve subtracting that from baseline) measured by the two assays (r = 0.85, P = .002). By contrast, plasma glucagon measured by the new Millipore RIA kit showed a numerical, although not statistically significant, increase following intraduodenal glucose infusion. No correlation was observed between the integrated glucagon response relative baseline measured by the new Millipore RIA kit and the Mercodia ELISA kit. In study 2, plasma samples were obtained before and after a 50 g oral glucose load from 10 individuals who had undergone Roux-en-Y gastric bypass (RYGB) for the management of obesity. As shown in Figure 1D–F, measurement of glucagon by the Mercodia ELISA kit revealed glucagon suppression after oral glucose, while an apparent stimulation of glucagon was observed with the new Millipore RIA kit. Not surprisingly, there was no correlation between the integrated glucagon response measured by the Mercodia ELISA kit and the newMillipore RIA kit. These observations raise a major concern that the current Millipore RIA kit may not provide accurate measurement of glucagon in humans, particularly when postprandial L-cell–derived hormones are increased many-fold (as is the case after RYGB). Given the wide application of the current RIA kit from Millipore for measurement of glucagon in clinical studies, we believe the observed marked discrepancies in plasma glucagon levels with the current RIA kit from Millipore warrant immediate attention from the scientific community. Our data also suggest that the RIA kit manufactured prior to the change of antibody for glucagon was acceptable for evaluation of circulating glucagon levels in clinical settings (although suppression by glucose was not always clearly shown, when compared with more sensitive assays). Although the company has indicated that the new antibody for glucagon showed no obvious cross-reaction with oxyntomodulin (<0.1%), glucagon-like peptide-1, glicentin, insulin, proinsulin, C-peptide, somatostatin or pancreatic polypeptide, our in vitro spike-in recovery analysis of oxyntomodulin at concentrations of 50 and 500 pmol/L using the new Millipore RIA kit yielded a recovery of 10.9% and 95.84% in buffer, and 45.34% and 80.35% in plasma, respectively. These observations are indicative of considerable cross-reactivity of the new antibody with oxyntomodulin, which may have accounted for the observed increases in plasma glucagon after intraduodenal and oral glucose that were detected by this assay. The major shift in the performance of the Millipore RIA kit after changing an antibody for Received: 25 January 2022 Revised: 16 February 2022 Accepted: 16 February 2022
No takes yet. Share an insight, caveat, or question.
Wu et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: