Why the study?
Do microelectrode electrograms improve the determination of catheter-tissue contact compared to standard bipolar electrograms in patients undergoing ablation of typical atrial flutter?
Do microelectrode electrograms improve the determination of catheter-tissue contact compared to standard bipolar electrograms in patients undergoing ablation of typical atrial flutter?
Microelectrode electrograms, particularly frequency content, amplitude, and injury current, provide superior real-time assessment of catheter-tissue contact compared to standard bipolar electrograms during atrial flutter ablation.
Answers are grounded in this paper and cite their sources.
mEGMs may aid contact assessment during ablation; leaves open superiority over sEGMs in larger prospective studies.
Background The utility of standard distal bipolar electrograms ( sEGM s) for assessing catheter‐tissue contact may be obscured by the presence of far‐field signals. Microelectrode electrograms ( mEGM s) may overcome this limitation. Methods We compared 5 mEGM characteristics (amplitude, frequency content, temporal signal variability, presence of injury current, and amplitude differential between bipoles) with the sEGM for determining tissue contact in 20 patients undergoing ablation of typical atrial flutter. Visualization of catheter‐tissue contact by intracardiac echocardiography ( ICE ) served as the gold standard for assessing contact. Correlation between electrograms and ICE ‐verified contact level was reported as percent concordance. Results Three of 5 mEGM characteristics demonstrated significantly better concordance with ICE ‐verified contact level than the sEGM (52% concordance with ICE ): mEGM frequency content (59% concordance with ICE , P < .001 for comparison with sEGM ); mEGM amplitude (concordance 59%, P < .001); and mEGM presence of injury current (56% concordance, P = .001). Concordance of amplitude differential between mEGM bipoles with ICE (49%) was not significantly different than the sEGM ( P = .638) whereas mEGM temporal variability (39%) was significantly worse than the sEGM . Using a median of all 5 mEGM characteristics provided additive information (concordance with ICE 64%) and was significantly better than all of the individual mEGM characteristics except frequency content ( P = .976). Conclusion Microelectrode EGM s (in particular frequency content, amplitude, and presence of injury current) can improve real‐time assessment of catheter contact compared to the use of standard bipolar EGM s. Broader use of mEGM s may enhance ablation efficacy.
No takes yet. Share an insight, caveat, or question.
Levy et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: