Why the study?
Although aPTT has historically been the standard for monitoring unfractionated heparin in mechanical circulatory support, it is being progressively superseded by the anti-Xa method.
Does anti-Xa monitoring align with aPTT monitoring for intravenous unfractionated heparin in total artificial heart recipients?
Does anti-Xa monitoring align with aPTT monitoring for intravenous unfractionated heparin in total artificial heart recipients?
In total artificial heart recipients on intravenous unfractionated heparin, anti-Xa and aPTT target ranges are poorly aligned, with anti-Xa guided therapy resulting in lower than predicted aPTT levels.
Should not yet change TAH anticoagulation monitoring; leaves optimal aPTT/anti-Xa alignment open for prospective study.
Although the activated partial thromboplastin time (aPTT) has historically been the method of choice for anticoagulation monitoring in patients undergoing mechanical circulatory support with intravenous unfractionated heparin, it is being progressively superseded by the anti-factor Xa (anti-Xa) method. A retrospective single-arm, single-centre analysis of 20 patients who underwent total artificial heart implantation entailed simultaneous determinations of aPTT and anti-Xa. Agreement between these parameters was assessed using the Bland-Altman method. Despite a positive correlation between aPTT and anti-Xa, normal target ranges were poorly aligned: from 5th to 30th postoperative day, for anti-Xa values of 0.2 and 0.4 U/ml corresponding aPTT values were 52.1 and 65.2 s, 7.9 and 14.8 lower than predicted values, respectively. This was not associated with thromboembolic sequalae. It was not possible to demonstrate a significant relationship between the predictor variables (postoperative day; white blood cell count; C-reactive protein concentration; alanine transaminase and alkaline phosphatase level; bilirubin; haemoglobin; albumin and total protein concentration) and the agreement between aPTT and anti-Xa levels. In summary, when anti-Xa levels were used to guide anticoagulation therapy, corresponding aPTT levels were low with respect to target range. Methodology applied in this study is generalizable to other forms of mechanical circulatory support.
No takes yet. Share an insight, caveat, or question.
Monteagudo‐Vela et al. (2021) studied this question.