Answers are grounded in this paper and cite their sources.
The aim of this study was to determine the risk factors for immune-related adverse events (irAEs) induced by immune checkpoint inhibitors. The authors conducted a retrospective study in which patients with malignant melanoma, non-small-cell lung cancer, gastric cancer or renal cell carcinoma who received anti-PD-1/PD-L1 antibodies were included. Of 247 patients, 118 developed a total of 182 irAEs. In the multivariate Fine-Gray regression analysis, serum albumin level ≥3.6 g/dl (hazard ratio: 1.62; 95% CI: 1.10-2.39; p = 0.015) and history of Type I hypersensitivity reactions (hazard ratio: 1.48; 95% CI: 1.02-2.14; p = 0.037) were significantly associated with the development of irAEs. High serum albumin levels and history of Type I hypersensitivity reactions are risk factors for irAEs.
No takes yet. Share an insight, caveat, or question.
Shimozaki et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: