Why the study?
His bundle pacing offers a more physiologic alternative to right ventricular pacing, but real-life procedural data using this technology are scarce.
Electroanatomic-guided His bundle pacing is feasible with a high implantation success rate and favorable electrical parameters.
Answers are grounded in this paper and cite their sources.
Supports mapping-guided His bundle pacing feasibility; leaves open its role versus traditional methods pending larger trials.
Funding Acknowledgements Type of funding sources: None. Background Patients with bradyarrhythmia in need for ventricular pacing may suffer from pacing-induced heart failure due to unphysiological right ventricular pacing. His bundle pacing (HBP) allows to overcome this common issue with a more physiologic approach but real-life procedural data using this technology is scarce. Methods We report a single centre experience of the first 44 consecutive patients being implanted with a His-bundle-based pacemaker 09/2020-11/2021 per 3D-mapping guided implantation due to different types of bradyarrhythmia, or for cardiac resynchronisation therapy in heart failure combined with a left-ventricular lead (HOT-CRT) ± a right ventricular defibrillator lead. The positioning of the His-bundle-lead was done by identifying the His-bundle-location with a 3D electroanatomic mapping system via an introducing sheath that is provided with electrodes at its tip. Results Mean age was 70 [16;86] years, 12/44 (27%) patients were female, mean baseline LVEF was 44±18%. Baseline ECG was captured: QRS width was 123±33ms, with typical LBBB in 14/44 (32%), typical RBBB in 4/44 (9%), alternating BBB in one patient (2%) and either no BBB or ventricular escape rhythm in 25/44 (57%). Indications for implantation were AV-block grade II-III in 19/44 (43%), primary prophylactic ICD indication in HFrEF in 13/44 (30%), atrial fibrillation with bradycardic conduction in 7/44 patients (16%), sick-sinus-syndrome in 4/44 (9%) and secondary prophylactic ICD indication in one patient (2%). In 41/44 (93%) a primary device was implanted, in 3/44 (7%) a pre-existent device was upgraded with a HB lead. Therefore, 14 dual-chamber-pacemaker, 5 single-chamber-pacemaker, 8 single-chamber CRT-P, 11 dual-chamber CRT-P, 4 single-chamber CRT-D, 2 dual-chamber CRT-D were implanted. In 50 patients HBP was attempted, while in 6/50 (12%) patients outside of this analysis the attempt was not successful, these patients were consecutively implanted with a non-HBP-device and therefor excluded from the further analysis. In the 44 patients included in this analysis with primary successful HBP, 4/44 (9%) his-bundle-leads dislocated within the first 48 hours, leading to a secondary success rate of 91%. There were two post-procedural pneumothorax that needed drainage, no major procedure-related complications occurred. Median skin-to skin procedure time was 109±50 minutes. The paced QRS width at the post-implantation follow up was 115±32ms with a change in QRS width of -10ms (+72;-92ms). When excluding the secondary lead dislocations and including only the successful HB paced QRS complexes, the paced QRS width was 105±30ms and the change in QRS width was -12±42ms. The mean his-bundle threshold was 1,2±1V over 0,5ms (0,5;1,5ms). The proportion of ventricular pacing was 69±38%. Conclusion Electroanatomic-guided His bundle pacing is feasible, with high implantation success rate and electric impact, both regarding QRS width and pacing threshold.
No takes yet. Share an insight, caveat, or question.
Rohrer et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: