Key result
Semiautomated VENC PC-MRI yields strongest agreement with TTE for severe AS at leaflet tips.
Why the study?
The reliability of semiautomated analysis of aortic stenosis parameters on velocity-encoded phase-contrast MR images in patients with severe aortic stenosis needed to be determined.
Does semiautomated analysis of velocity-encoded phase-contrast MR images reliably measure aortic stenosis parameters compared to echocardiography in patients with severe aortic stenosis?
Observational (n=55)
Does semiautomated analysis of velocity-encoded phase-contrast MR images reliably measure aortic stenosis parameters compared to echocardiography in patients with severe aortic stenosis?
The study aims to evaluate the reliability of semiautomated MRI analysis for assessing severe aortic stenosis compared to standard echocardiography.
Answers are grounded in this paper and cite their sources.
Further validation needed before semiautomated MRI replaces echocardiography for aortic stenosis; leaves open clinical reliability in severe cases.
Objective: The aim of the study was to determine the reliability of semiautomated analysis of aortic stenosis (AS) parameters on velocity-encoded (VENC) phase-contrast (PC) MR images in patients with severe AS. Materials and Methods:This study included 55 patients with severe AS and normal left ventricular ejection fraction who underwent transthoracic echocardiography (TTE) and VENC PC sequencing.Aortic valve area (AVA) and transvalvular velocity were measured semiautomatically with commercial software at three aortic valve levels [the level of the aortic leaflet tips (0 mm) and 6 mm upstream and downstream of the leaflet tips].The AVA was drawn on VENC PC images, and the maximum, minimum, and average were calculated.The peak and mean transaortic pressure gradient (PG) were calculated with a modified Bernoulli equation.All estimates were compared with TTE values by using the concordance correlation coefficient (CCC).Results: Estimates at the 0 mm level were more highly correlated with TTE values (parameter, CCC): peak velocity, 0.394; average AVA, 0.735; maximum AVA, 0.538; peak PG, 0.539; and mean PG, 0.048.Among these parameters, average AVA0 mm had the highest reliability.Conclusion: If AS parameters are measured on VENC PC sequences, average AVA0 mm should be considered as a parameter for diagnosing severe AS.
No takes yet. Share an insight, caveat, or question.
Bak et al. (2017) conducted an observational in Severe aortic stenosis (n=55). Semiautomated analysis of velocity-encoded phase-contrast MR images vs. Transthoracic echocardiography (TTE) was evaluated on Reliability of aortic stenosis parameters compared with TTE using concordance correlation coefficient (CCC) (CCC 0.735 (average AVA at 0 mm)). Semiautomated VENC PC-MRI analysis of average aortic valve area at the leaflet tips (0 mm) showed the highest reliability compared with TTE in severe AS.