Why the study?
Does extended external loop recorder monitoring improve diagnostic yield in patients with unexplained syncope or palpitations?
Does extended external loop recorder monitoring improve diagnostic yield in patients with unexplained syncope or palpitations?
Extended external loop recorders provide a high diagnostic yield for unexplained palpitations and a moderate yield for syncope, suggesting they could be used as a stepwise approach before implantable loop recorders.
Answers are grounded in this paper and cite their sources.
Supports stepwise external monitoring before ILRs for unexplained symptoms; hypothesis-generating and requires prospective validation.
AIMS: To assess the diagnostic yield of new external loop recorders (ELRs) in patients with history of syncope, pre-syncope, and sustained palpitations. METHODS AND RESULTS: Since 2005, we have established a registry including patients who consecutively received ELR monitoring for unexplained syncope or pre-syncope/palpitations. The registry included 307 patients (61% females, age 58 ± 19 years, range 8-94 years) monitored by high-capacity memory ELR of two subsequent generations: SpiderFlash-A(®) (SFA(®), Sorin CRM), storing two-lead electrocardiogram (ECG) patient-activated recordings by loop-recording technique (191 patients, 54 patients with syncope, years 2005-09), and SpiderFlash-T(®) (SFT(®)), adding auto-trigger detection for pauses, bradycardia, and supraventricular/ventricular arrhythmias (116 patients, 38 patients with syncope, years 2009-12). All the patients previously underwent routine workup for syncope or palpitation, including one or more 24 h Holter, not conclusive for diagnosis. Mean monitoring duration was 24.1 ± 8.9 days. Among 215 patients with palpitations, a conclusive diagnosis was obtained in 184 patients (86% diagnostic yield for palpitation). Among 92 patients with syncope, a conclusive diagnosis was obtained in 16 patients (17% clinical diagnostic yield for syncope), with recording during syncope of significant arrhythmias in 9 patients, and sinus rhythm in 7 patients. Furthermore, asymptomatic arrhythmias were de novo detected in 12 patients (13%), mainly by auto-trigger detection, suggesting an arrhythmic origin of the syncope. CONCLUSIONS: The diagnostic yield of ELR in patients with syncope, pre-syncope, or palpitation of unknown origin after routine workup was similar to implantable loop recorder (ILR) within the same timeframe, therefore, ELR could be considered for patients candidate for long-term ECG monitoring, stepwise before ILR.
No takes yet. Share an insight, caveat, or question.
Locati et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: