Atypical AV nodal reentry with a bystander accessory pathway is an unusual mechanism of preexcited tachycardia that can be identified by specific electrophysiological pacing and ablation responses.
Answers are grounded in this paper and cite their sources.
May aid EP differentiation of preexcited tachycardias in select cases; leaves open validation in larger cohorts.
We present an unusual mechanism of preexcited tachycardia--atypical AV nodal reentry with bystander AP. It can be differentiated from other preexcited tachycardias by its variable degree of preexcitation (either spontaneous or in response to atrial pacing), higher degree of preexcitation with pacing near the origin of the AP than during tachycardia, inability to preexcite the tachycardia by either late atrial or ventricular premature beats, the presence of nonpreexcited atypical AV nodal reentry tachycardia following successful AP ablation, and by exclusion of atrial tachycardia.
No takes yet. Share an insight, caveat, or question.
Glikson et al. (1999) studied this question.