Why the study?
Does the use of resterilized pacemakers reduce the composite of unexpected battery depletion, infection, and device dysfunction in patients requiring pacemakers?
Does the use of resterilized pacemakers reduce the composite of unexpected battery depletion, infection, and device dysfunction in patients requiring pacemakers?
Reuse of pacemakers is a feasible and safe option that is non-inferior to new devices for major safety outcomes, though associated with a higher rate of explantation.
Answers are grounded in this paper and cite their sources.
No significant difference in primary endpoint with reused pacemakers; leaves open equivalence to new devices in randomized trials.
BACKGROUND: In developing economies, there are patients in whom pacemaker implantation is delayed because they cannot afford one. Reused devices have been a solution. To address concerns about safety, a cohort of consecutive patients implanted with a reused pacemaker was compared with a control group. METHODS AND RESULTS: A cohort of 603 consecutive patients from 2000 to 2010 was studied in an ambispective noninferiority study. The study group patients (n=307) received resterilized pacemakers, and the control group patients (n=296) received a new pacemaker. A combined end point of 3 major outcomes-unexpected battery depletion, infection, and device dysfunction-was analyzed. A total of 85 pacemakers had to be explanted, 31 in the control group (10.5%) and 54 in the study group (17.6%; relative risk, 1.68; 95% confidence interval, 1.1-2.5; P=0.02). Forty-three reached the primary end point, 16 in the control group (5.5%) and 27 in the study group (7.2%; relative risk, 1.3; 95% confidence interval, 0.70-2.45; P=0.794). In terms of individual outcomes, 5 new pacemakers (1.7%) and 11 resterilized pacemakers (3.6%) had unexpected battery depletion (relative risk, 2.12; 95% confidence interval, 0.75-6; P=0.116); 3.7% new pacemakers and 3.2% reused pacemakers had a procedure-related infection (relative risk, 0.87; 95% confidence interval, 0.38-2.03; P=0.46); and 1 pacemaker in the study group malfunctioned. CONCLUSIONS: Pacemaker reuse is feasible and safe and is a viable option for patient with bradyarrhythmias. Other than the expected shorter battery life, reuse of pacemaker generators is not inferior to the use of new devices.
No takes yet. Share an insight, caveat, or question.
Nava et al. (2013) studied this question.