Why the study?
Does forearm blood pressure measurement using a standard cuff differ from upper arm measurement using an appropriate sized cuff in obese young adults?
Does forearm blood pressure measurement using a standard cuff differ from upper arm measurement using an appropriate sized cuff in obese young adults?
Forearm blood pressure measurements using standard cuffs overestimate blood pressure compared to upper arm measurements with appropriately sized cuffs in obese young adults.
Answers are grounded in this paper and cite their sources.
Forearm BP may overestimate values with standard cuffs in obese young adults; leaves open effects on hypertension classification pending prospective validation.
The prevalence of obesity is increasing in Indian youth and obesity is associated with complications like systemic hypertension. Often, due to the non-availability of appropriate sized cuffs, standard cuff bladders are used to measure blood pressure in the forearms of obese young adults. To compare the upper arm arterial blood pressure measured using an appropriate cuff with the forearm arterial blood pressure measured using a standard cuff and conventional sphygmomanometry in obese otherwise healthy first year medical students. Blood pressure was measured in 27 obese otherwise healthy first year medical students after five minutes of rest using a mercury sphygmomanometer with the subjects seated and the arm and forearm at heart level, using an appropriate sized cuff for the upper arm according to American Heart Association standards and a standard cuff for the fore arm. A statistically significant difference in both systolic [t-test (paired) = -6.921; df = 26; sig =.000 (2-tailed)] and diastolic blood pressure [t-test (paired) = 8.508; df = 26; sig =.000 (2-tailed)] was found, with the blood pressure readings being higher in the forearm. The correlations between upper arm and forearm systolic and diastolic blood pressure were 0.785 (p =.000) and 0.870 (p =.000). Both systolic and diastolic blood pressure measurements were significantly higher in the forearm. Further studies with larger sample size should be conducted to confirm that forearm blood pressure measurements using standard cuff bladders cannot be considered equal to upper arm measurements made using an appropriate sized cuff in all young obese individuals
No takes yet. Share an insight, caveat, or question.
Suganthi et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: