Percutaneous transcatheter closure of coronary fistulas is feasible but carries a risk of catastrophic complications such as device recoil into epicardial vessels.
Answers are grounded in this paper and cite their sources.
Supports feasibility of percutaneous coronary fistula closure despite device risks; leaves open need for safer techniques and larger studies.
This study details different methodologies of percutaneous closure of arteriosystemic and arteriovenous coronary fistula. Seven patients underwent transcatheter intervention of 10 fistulas, with 7 fistulas successfully closed: 6 with embolic coil devices and 1 with a covered stent obstructing the fistula ostium. The major complication encountered was one death as a result of device recoil into a major epicardial vessel. Percutaneous transcatheter closure of coronary fistulas appears to be simple, facile, and effective. However, device recoil into an undesired arterial segment, while irritating in a noncoronary arterial tree, may be catastrophic when occurring in an epicardial coronary artery.
No takes yet. Share an insight, caveat, or question.
Dorros et al. (1999) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: