Why the study?
In horses, pulmonary artery stiffness has only been measured from the right parasternal short-axis view, and the influence of alternative imaging windows remains unknown.
Does the left parasternal angled view provide repeatable and reproducible measurements of pulmonary artery stiffness compared to the right parasternal short-axis view in Thoroughbred racehorses?
Does the left parasternal angled view provide repeatable and reproducible measurements of pulmonary artery stiffness compared to the right parasternal short-axis view in Thoroughbred racehorses?
Pulmonary artery stiffness can be consistently measured from the left parasternal angled view in Thoroughbred racehorses, yielding higher values than the right parasternal view likely due to better Doppler beam alignment.
Answers are grounded in this paper and cite their sources.
Enables alternative left parasternal PAS measurement in horses; leaves open view standardization and clinical thresholds.
BACKGROUND: Pulmonary Artery Stiffness (PAS) is a non-invasive echocardiographic index of pulmonary artery elasticity. In horses, PAS has been measured only from the right parasternal short-axis view, while the influence of alternative imaging windows remains unknown. AIMS/OBJECTIVES: To assess the repeatability and reproducibility of Acceleration Time (AT), Maximal Frequency Shift (MFS), and PAS measurements from the left parasternal angled view of the right ventricular inflow/outflow, and to compare these parameters with those obtained from the right parasternal short-axis view in Thoroughbred racehorses. METHODS: Forty Thoroughbreds underwent pulsed-wave Doppler echocardiography from both right and left parasternal views. Measurements included AT, MFS, and PAS (MFS/AT). The intra-class correlation coefficient (ICC) and the coefficients of variation (CV) were used to assess intra-operator repeatability and inter-operator (three operators) reproducibility in 40 horses, day-to-day (two different days) repeatability in 5 horses, and inter-operator (two operators) reproducibility for image acquisition in 10 horses. The Wilcoxon signed-rank test was used to compare left and right parasternal measurements in 40 horses. RESULTS: Intra-operator agreement was excellent for all parameters (AT: ICC=0.94; MFS: ICC=0.95; PAS: ICC=0.97). Inter-operator agreement ranged from moderate to excellent (AT: ICC=0.63-0.87; MFS: ICC=0.96-0.99; PAS: ICC=0.83-0.96). Day-to-day agreement was good for AT (ICC=0.80) and MFS (ICC=0.71), and excellent for PAS (ICC=0.98). Inter-observer agreement for image acquisition ranged from good to excellent (AT: ICC=0.97, MFS: ICC=0.86, PAS: ICC=0.94). Compared to the right view, the left parasternal view showed lower AT (110 vs. 151 ms), higher MFS (2.6 vs. 2.27 kHz), and higher PAS (23.8 vs. 15.6 kHz/s) (all p<0.001). CONCLUSION: PAS can be consistently measured from the left parasternal angled view in Thoroughbred racehorses. PAS was higher when measured from the left parasternal window, possibly due to a better alignment of the Doppler beam with the pulmonary artery flow.
No takes yet. Share an insight, caveat, or question.
Bozzola et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: