Answers are grounded in this paper and cite their sources.
Increased plasma total homocysteine (tHcy), a sulfur amino acid, is an important risk factor for vascular disease (1) and for arterial and venous thromboembolism (2). Several techniques have been developed to measure plasma or serum tHcy concentrations (3). Given the extension of this determination to routine clinical chemistry laboratories, an immunoassay has been developed for use with the AxSYM analyzer (4). The AxSYM is a completely automated system, which allows immediate and continuous access. We evaluated the analytical performance of the automated AxSYM assay and compared it with the IMx Hcy assay (5), a method widely used for tHcy determination in laboratories. Both methods use reduction of protein-bound Hcy by dithiothreitol, conversion of Hcy to S-adenosylhomocysteine in the presence of adenosine catalyzed by hydrolase enzyme and detection of S-adenosylhomocysteine by fluorescence polarization immunoassay. The AxSYM assay, however, gives the first result within 35 min (rather than 60 min) and allows random access. The AxSYM assay does not require sample pretreatment, and serum or plasma may be used. The assay requires 108 μL of sample, and up to 60 samples can be processed in 1 h (20 for the IMx). The linearity of the method was confirmed up to 50 μmol/L (i.e., the highest calibrator concentration). Linearity was assessed by serially diluting (1:2, 1:4, 1:8, 1:16, and 1:32) three high-tHcy concentration plasmas (>40 μmol/L) with AxSYM buffer. Sample dilutions were processed in duplicate. The results (in percentage of theoretical concentrations) showed values between 96.8% and 103.2%. Linearity was not tested above 50 μmol/L, which is the upper limit allowed by the software based on the calibrator values. To determine the limit of detection, we analyzed 10 replicates of the A calibrator (0 μg/L) and 2 replicates of the B calibrator (2.5 μmol/L) in four runs (6). The average limit of detection was 0.3 μmol/L. The three controls [low (7 μmol/L), medium (12.5 μmol/L), and high (25 μmol/L)] for the Abbott IMx system were analyzed in replicates of 20 over 3 consecutive days. Within-run CVs [3.5% (low), 2.7% (medium), and 2.3% (high)] were satisfactory and similar to those reported for the IMx assay (7). To determine between-day imprecision, each of these three controls was analyzed over 20 different consecutive days: CVs were 3.8% (low), 2.9% (medium), and 2.3% (high), indicating a good precision for the method. The addition to two normal plasmas of physiological and 10-fold physiological concentrations of methionine (30 and 300 μmol/L), cysteine (50 and 500 μmol/L), or cystine (70 and 700 μmol/L) showed tHcy results 99.4% of baseline after methionine addition, 96.2% after cysteine addition, and 102.4% after cystine addition. Plasma samples from 100 patients were analyzed by both the AxSYM and IMx tHcy assays during a 10-week period. All of these patients were scheduled for routine tHcy determination, and clinical practice complied with the ethics rules of our institution. Plasma samples were stored at −20 °C before assay and were analyzed simultaneously on both analyzers. Deming regression (see Fig. 1 ) showed an excellent agreement between the two methods (y = 1.04x − 0.05; r = 0.99; P <0.001; Sy|x = 0.8964; 95% confidence interval for the slope, 1.015–1.058; 95% confidence interval for the intercept, −0.320 to 0.363 μmol/L). In conclusion, the tHcy AxSYM method shows good accuracy and precision and correlates highly with the IMx assay. Furthermore, the AxSYM method is less time-consuming and benefits from the analyzer’s random/continuous mode. The tHcy AxSYM assay is therefore suitable for routine use in the clinical laboratory. Correlation of IMx tHcy assay with the AxSYM tHcy assay (Deming regression plot): study of 100 patient plasma samples. This work was supported in part by Abbott Laboratories. We are indebted to S. Kerguelen and M. Waroux for their constant support.
No takes yet. Share an insight, caveat, or question.
Pernet et al. (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: