Key result
Autopsy analysis of 4 patients up to 350 days post-CoreValve implantation demonstrated early fibrin deposition and inflammation, followed by progressive neointimal coverage.
Why the study?
What are the anatomo-pathological changes over time after percutaneous aortic valve replacement with the CoreValve Revalving System?
Observational (n=4)
What are the anatomo-pathological changes over time after percutaneous aortic valve replacement with the CoreValve Revalving System?
Answers are grounded in this paper and cite their sources.
Anatomo-pathological assessment of the CoreValve Revalving System up to 350 days post-implantation shows encouraging neointimal coverage of the native valve site without excessive pannus formation on the leaflets.
AIMS: Significant technological improvements have made percutaneous aortic valve replacement (PAVR) simpler and safer, but the behaviour of the implanted valve over time remains unknown. We report the anatomo-pathological analysis of patients who died at different time intervals post PAVR with the CoreValve Revalving System. METHODS AND RESULTS: In our early experience, 21 patients underwent CoreValve implantation between 12/2005 and 02/2007. Among the 11 deaths at one year follow-up, four patients had an autopsy with macro and microscopic analysis. The device was divided in three parts during pathological assessment: the lower portion (area 1), the leaflets (area 2) and the upper part (area 3). The CoreValves were implanted for 3, 13, 104 and 350 days. Gross examination showed neointimal tissue covering most of the frame struts in contact with the aortic wall, but areas of high velocity blood flow were bare. Histopathology examination demonstrated fibrin deposition and inflammatory response early after valve implantation, followed by neointimal coverage with progressive regression of the inflammatory response over time. CONCLUSIONS: While waiting for results of longer term PAVR echocardiographic follow-up, the anatomic assessment is encouraging with neointimal coverage of the native valve site and no excessive pannus formation occurring over the valve leaflets.
No takes yet. Share an insight, caveat, or question.
Noble et al. (2009) conducted an observational in Aortic valve disease requiring percutaneous aortic valve replacement (n=4). CoreValve Revalving System implantation was evaluated on Anatomo-pathological analysis (macroscopic and microscopic). Autopsy analysis of 4 patients up to 350 days post-CoreValve implantation demonstrated early fibrin deposition and inflammation, followed by progressive neointimal coverage.
Synapse has enriched 10 related papers. Consider them for comparative context: