Key result
Preoperative TEE findings, such as fibrous tissue binding to the right ventricular wall (OR 2.167, p<0.001) and lead-to-lead binding sites (OR 3.034, p<0.05), predicted TLE technical difficulties and major complications.
Why the study?
Echocardiographic phenomena identified by TEE during preoperative evaluation may determine the difficulty and safety of transvenous lead extraction procedures.
Does preoperative transesophageal echocardiography predict technical difficulties and complications in patients undergoing transvenous lead extraction?
Observational (n=936)
No
Does preoperative transesophageal echocardiography predict technical difficulties and complications in patients undergoing transvenous lead extraction?
Odds Ratio: 2.167
p-value: p=< 0.001
Preoperative transesophageal echocardiography can identify specific lead-related phenomena, such as fibrous tissue binding and lead-to-lead binding, which predict technical difficulties and major complications during transvenous lead extraction.
BACKGROUND: Transesophageal echocardiography (TEE) is a useful tool in preoperative evaluation of patients undergoing transvenous lead extraction (TLE). HYPOTHESIS: Echocardiographic phenomena may determine the difficulty and safety of the procedure. METHODS: Data from 936 transesophageal examinations (TEE) performed at a high volume center in patients awaiting TLE from 2015 to 2019 were assessed. RESULTS: TEE revealed a total of 1156 phenomena associated with the implanted leads in 697 (64.85%) patients, including: asymptomatic masses on endocardial leads (AMEL) (58.65%), vegetations (12,73%), fibrous tissue binding the lead to the vein or heart wall (33.76%), lead-to-lead binding sites (18.38%), excess lead loops (19.34%), intramural penetration of the lead tip (16.13%) and lead-dependent tricuspid dysfunction (LDTD) (6.41%). Risk factors for technical difficulties during TLE in multivariate analysis were: fibrous tissue binding the lead to atrial wall (OR = 1.738; p < 0.05), to right ventricular wall (OR = 2.167; p < 0.001), lead-to-lead binding sites (OR = 1.628; p < 0.01) and excess lead loops (OR = 1.488; p < 0.05). Lead-to-lead binding sites increased probability of major complications (OR = 3.034; p < 0.05). Presence of fibrous tissue binding the lead to the superior vena cava (OR = 0.296; p < 0.05), right atrial wall (OR = 323; p < 0.05) and right ventricular wall (OR = 0.297; p < 0.05) reduced the probability of complete procedural success, whereas fibrous tissue binding the lead to the tricuspid apparatus decreased the probability of clinical success (OR = 0.307; p < 0.05). CONCLUSIONS: Careful preoperative TEE evaluation of the consequences of extended lead implant duration (enhanced fibrotic response) increases the probability of predicting the level of difficulty of TLE procedures, their efficacy and risk of major complications.
No takes yet. Share an insight, caveat, or question.
Nowosielecka et al. (2021) conducted an observational in Patients awaiting transvenous lead extraction (TLE) (n=936). Preoperative transesophageal echocardiography (TEE) phenomena (e.g., fibrous tissue binding, lead-to-lead binding) vs. Absence of these echocardiographic phenomena was evaluated on Technical difficulties during TLE (fibrous tissue binding to right ventricular wall) (OR 2.167, p=< 0.001). Preoperative TEE findings, such as fibrous tissue binding to the right ventricular wall (OR 2.167, p<0.001) and lead-to-lead binding sites (OR 3.034, p<0.05), predicted TLE technical difficulties and major complications.