Key result
Serum NT-proBNP levels were higher in patients with asymptomatic diastolic dysfunction compared to controls, yielding a sensitivity of 94.2% and specificity of 88.1%.
Why the study?
Does serum NT-proBNP correlate with asymptomatic left ventricular diastolic dysfunction in patients with preserved ejection fraction?
Case-Control (n=35)
No
Does serum NT-proBNP correlate with asymptomatic left ventricular diastolic dysfunction in patients with preserved ejection fraction?
Serum NT-proBNP levels correlate significantly with tissue Doppler indices of diastolic dysfunction and may serve as a sensitive biomarker for detecting asymptomatic diastolic dysfunction in patients with preserved ejection fraction.
Answers are grounded in this paper and cite their sources.
May support NT-proBNP screening for asymptomatic diastolic dysfunction; hypothesis-generating and leaves clinical utility open pending validation.
Objective: To study the correlation between plasma level of N-terminal pro-BNP and left ventricular diastolic dysfunction in asymptomatic patients. Methods: The study included 35 patients divided into control group: included 10 patients with normal systolic and diastolic function and patient group: included 25 patients with normal systolic and asymptomatic diastolic dysfunction. The patients were evaluated by conventional echocardiography (diameters, systolic and diastolic function) and tissue Doppler (early diastolic velocity) then E/e` was measured. Serum pro BNP was measured and correlated with demographic and echocardiographic parameters and its sensitivity, specificity were evaluated. Results: Both groups were of comparable age, gender, BMI, risk factors and systolic function. By Doppler echocardiography there was no difference in E velocity between two groups (0.64+0.18 m/sec Vs 0.67+0.14 P = 0.302), but by tissue Doppler there was significant difference in the mean value of e` velocity (m/sec) (0.14+0.06 Vs 0.06+0.01 P=0.001) and E/e (5.03+0.149 Vs 0.55+1.79 P= 0.001). There was significant difference between two groups according to serum NT pro BNP (ng/ml) was (59.1) in the control group Vs (154.1) in patient group (P = 0.001). There was significant correlation between serum NT pro BNP and E (P= 0.001) and E/e` (P = 0.001). The sensitivity of serum NT Pro BNP was 94.2, specificity was 88.1, positive predictive value was 90.6 and its accuracy was 86.2. Conclusion: Serum level of NT pro BNP can be used as innovative method in predicting asymptomatic diastolic dysfunction and so prevent the progression to symptomatic diastolic heart failure.
No takes yet. Share an insight, caveat, or question.
Arafa et al. (2015) conducted a case-control in Asymptomatic left ventricular diastolic dysfunction (n=35). Serum NT-proBNP level vs. Normal diastolic function was evaluated on Mean serum NT-proBNP level (ng/ml) (p=0.001). Serum NT-proBNP levels were higher in patients with asymptomatic diastolic dysfunction compared to controls, yielding a sensitivity of 94.2% and specificity of 88.1%.