Key result
CMR provides comprehensive tissue characterization and functional assessment to identify heart failure etiology.
Cardiovascular magnetic resonance serves as the gold standard for ventricular volume and function quantification while providing unique non-invasive tissue characterization (such as late gadolinium enhancement and T2 imaging) that differentiates ischemic from non-ischemic heart failure etiologies and guides revascularization and medical therapy.
Answers are grounded in this paper and cite their sources.
CMR may streamline HF etiology evaluation in select cases; leaves open prospective trials on management impact.
eart failure is a common disorder that is associated with significant morbidity, mortality and financial burden to healthcare services.In the UK, around 900 000 people have been diagnosed with heart failure and the prevalence of the condition increases as the population ages.w1 Population-based studies suggest that heart failure carries a worse prognosis than breast and colon cancer, with estimates suggesting a 1 year mortality of 40% from the time of diagnosis.Heart failure currently accounts for a total of one million inpatient bed days and admissions are projected to rise by 50% over the next 25 years.Heart failure treatment currently absorbs 1.8% of the total National Health Service budget, of which 70% is spent on hospitalisation.Accurate diagnosis, assessment and risk stratification of such patients by imaging modalities is important, particularly with the advent of effective but expensive implantable devices.In the last 5 years, there have been tremendous advances in the ability of cardiovascular magnetic resonance (CMR) to fulfil many of these needs and provide a comprehensive assessment. 1 A combination of hardware and software developments means that a modern CMR scanner is able to yield information on myocardial anatomy, function, tissue characterisation, viability, perfusion and flow within a single 45-60 min study. HOW DOES CMR WORK AND WHAT INFORMATION CAN IT PROVIDE? cBasic principles Understanding the way in which CMR works provides a basis for appreciating its role in evaluating patients with heart failure.CMR yields high contrast and high resolution images of the heart by mapping radio wave signals absorbed and emitted by hydrogen nuclei (protons) in a powerful magnetic field.Most cardiovascular pathologies manifest with an increase in water content which is rich in protons so that CMR is a sensitive guide to early disease states.CMR is currently mainly performed at a magnetic field strength of 1.5 Tesla (T).The two main types of sequences used are gradient echo and spin echo imaging techniques.Gradient echo techniques lead to blood and fat both appearing white.They enable the acquisition of cine images with a high temporal and spatial resolution that can be used to identify myocardial function and abnormal flow patterns.Velocity mapping is based on gradient echo and can be used in a similar way to two-dimensional Doppler or provide multidimensional flow imaging for complex flow dynamics problems.Based on the different relaxation properties of tissues such as fat, muscle, and areas of inflammation, a range of sequences can be used to enable tissue characterisation.T1-weighted spin echo techniques lead to blood appearing black, while fat appears white.They are useful for high resolution anatomical as opposed to functional imaging.T2-weighted spin echo sequences contain a water excitation pulse that can be used to highlight myocardial inflammation or oedema.Valvular function can be assessed both qualitatively from cine imaging as well as quantitatively from phase contrast velocity mapping with accurate measurements of peak velocity and regurgitant volumes.While most image acquisition is performed without the routine need for contrast agents, an important development has been the use of gadolinium-chelated contrast agents (Gd-CA), such as Gd-DTPA (gadolinium diethylenetriamine penta-acetic acid), to document perfusion defects, microvascular ischaemia and areas of scar tissue/fibrosis.Gd-CA has paramagnetic properties and thus gives a bright signal on scanning.It is metabolically inert and safe to administer via a peripheral line as a single bolus with a negligible risk of nephrotoxicity, although it is best avoided in patients with severe renal impairment.Due to its chemical properties and large molecular size, Gd-CA is unable to penetrate the intact myocyte membrane.However, it can passively diffuse and accumulate into the extracellular space around muscle cells or into myocytes where the cell membrane has been ruptured.The typical dose given is 0.1-0.2mmol/kg (usually between 12-40 ml).
No takes yet. Share an insight, caveat, or question.
Assomull et al. (2007) conducted a review in Heart failure and cardiomyopathies. Cardiovascular magnetic resonance (CMR) vs. Echocardiography, x-ray coronary angiography, SPECT, or PET was evaluated on Diagnostic accuracy, tissue characterization, myocardial viability, and risk stratification in heart failure. Cardiovascular magnetic resonance provides comprehensive assessment of myocardial anatomy, function, viability, perfusion, and fibrosis in a single 45-60 min study to determine heart failure etiology.
Synapse has enriched 10 related papers. Consider them for comparative context: