Key result
The machine learning-derived Cardi35 score significantly predicted inappropriate implantable cardioverter-defibrillator therapy with a hazard ratio of 1.62.
Why the study?
The study aimed to develop machine learning-based predictive models for identifying inappropriate ICD therapy.
Does the Cardi35 machine learning score predict inappropriate implantable cardioverter-defibrillator therapy in patients with ICDs?
Cohort (n=182)
No
Does the Cardi35 machine learning score predict inappropriate implantable cardioverter-defibrillator therapy in patients with ICDs?
Hazard Ratio: 1.62 (95% CI 1.32–1.98)
p-value: p=<0.001
A novel machine learning-derived score (Cardi35) using six clinical and ECG variables can effectively predict the risk of inappropriate ICD therapy.
ML models may flag inappropriate ICD therapy risk; leaves open whether they improve outcomes in practice.
We aimed to develop machine learning-based predictive models for identifying inappropriate implantable cardioverter-defibrillator (ICD) therapy. Our study included 182 consecutive cases (average age 62.2 ± 4.5 years, 169 men) and employed 14 non-deep learning models for prediction (hold-out method). These models utilized selected electrocardiogram parameters and clinical features collected after ICD implantation. From the feature importance analysis of the best ML model, we established easily calculable scores. Among the patients, 25 (13.7%) experienced inappropriate therapy, and we identified 16 significant predictors. Using recursive feature elimination with cross-validation, we reduced the features to six with high feature importance: history of atrial arrhythmia (Atr-arrhythm), ischemic cardiomyopathy (ICM), absence of diabetes mellitus (DM), lack of cardiac resynchronization therapy (CRT), V3 ST level at J point (V3 STJ), and V5 R-wave amplitudes (V5R amp). The extra-trees classifier yielded the highest area under receiver operating characteristics curve (AUROC; 0.869 on test data). Thus, the Cardi35 score was defined as [+ 5.5*Atr-arrhythm - 1.5*CRT + 1.0*V3STJ + 1.0*V5R - 1.0*ICM - 0.5*DM], which demonstrated a hazard ratio of 1.62 (P < 0.001). A cut-off value of the score + 5.5 showed high AUROC (0.826). The ML approach can yield a robust prediction model, and the Cardi35 score was a convenient predictor for inappropriate therapy.
No takes yet. Share an insight, caveat, or question.
Tateishi et al. (2023) conducted a cohort in Patients with implantable cardioverter-defibrillators (ICDs) (n=182). Cardi35 score vs. Lower score was evaluated on Inappropriate ICD therapy (HR 1.62, 95% CI 1.32-1.98, p=<0.001). The machine learning-derived Cardi35 score significantly predicted inappropriate implantable cardioverter-defibrillator therapy with a hazard ratio of 1.62.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: