Key result
Structural heart disease factors, such as baseline QRS duration (OR 1.24; 95% CI 1.15-1.33) and E/e' (OR 1.23), rather than pacing site, determined QRS prolongation during RV pacing.
Why the study?
Longer QRS duration during right ventricular pacing indicates poor prognosis, but the underlying mechanisms remain unclear.
Does underlying structural heart disease or pacing site determine QRS duration during right ventricular pacing in patients without bundle-branch block?
Observational (n=211)
Does underlying structural heart disease or pacing site determine QRS duration during right ventricular pacing in patients without bundle-branch block?
Odds Ratio: 1.24 (95% CI 1.15–1.33)
p-value: p=<0.01
Prolonged QRS duration during right ventricular pacing is primarily determined by underlying structural heart disease rather than the specific pacing site.
Structural heart disease may predict QRS prolongation with RV pacing; leaves open whether site selection modifies risk in patients without it.
Introduction: Right ventricular (RV) pacing causes changes in the heart’s electrical and mechanical activation patterns. QRS duration is a useful surrogate marker of electrical dyssynchrony; longer QRS duration during RV pacing indicates poor prognosis. However, the mechanisms underlying longer QRS duration during RV pacing remain unclear; hence, we investigated factors predicting QRS prolongation during RV pacing. Methods and Results: We enrolled 211 patients who underwent catheter ablation for supraventricular tachyarrhythmia and showed no bundle-branch-block. Three-dimensional mapping for QRS duration during RV pacing from the RV outflow to RV apex was performed, and the difference in QRS duration was analyzed. The predisposing factors causing QRS >160 ms during RV apical pacing were also analyzed. QRS durations at baseline and during RV pacing from the RV outflow and at RV apex were 85.0±7.5 ms, 163.7±17.1 ms, and 156.2±16.1 ms, respectively. With respect to QRS duration, there was a significant correlation between RV outflow and RV apical pacing (r=0.658, p<0.001). The difference in QRS duration between RV outflow and apex in each patient was only 12.5±10.4 ms. Logistic multivariable regression analysis identified baseline QRS duration [odds ratio (OR) 1.24, 95% confidence interval (CI) 1.15 to 1.33, p<0.01], interventricular septum thickness (OR 1.20, 95% CI 1.02-1.40, p=0.025), left atrial diameter (OR 1.08, 95% CI 1.01-1.16, p=0.024), and E/e’ (OR 1.23, 95% CI 1.12-1.35, p<0.01) as significant predictors of prolonged QRS duration during RV apical pacing. Conclusion: QRS duration during RV pacing largely depends not on the pacing site, but on underlying structural heart diseases.
No takes yet. Share an insight, caveat, or question.
Ogano et al. (2020) conducted an observational in Supraventricular tachyarrhythmia (n=211). Structural heart disease factors (baseline QRS, septum thickness, LA diameter, E/e') was evaluated on Prolonged QRS duration (>160 ms) during RV apical pacing (OR 1.24, 95% CI 1.15-1.33, p=<0.01). Structural heart disease factors, such as baseline QRS duration (OR 1.24; 95% CI 1.15-1.33) and E/e' (OR 1.23), rather than pacing site, determined QRS prolongation during RV pacing.