Key result
Prolonged paced QRS during RVAP linked to ~6-fold higher heart failure risk.
Why the study?
Does paced QRS duration predict heart failure events in patients with idiopathic complete atrioventricular block receiving right ventricular apical pacing?
Cohort (n=194)
Does paced QRS duration predict heart failure events in patients with idiopathic complete atrioventricular block receiving right ventricular apical pacing?
Absolute Event Rate: 56.8% vs 9.4%
p-value: p=< 0.001
Prolonged paced QRS duration during right ventricular apical pacing predicts long-term cardiac function decline and heart failure events in patients with complete atrioventricular block.
May support paced QRS for HF risk stratification after RV apical pacing; leaves open whether QRS-shortening strategies reduce events.
AIMS: The aim of this study was to investigate the predictive ability of paced QRS duration (pQRSd) for heart failure events among patients receiving right ventricular apical pacing (RVAP). METHODS AND RESULTS: A total of 194 patients with complete atrioventricular block receiving pacemaker treatment were enrolled and stratified to group 1, pQRSd < 160 ms, n = 53; group 2, 160 ≤ pQRSd < 190 ms, n = 97; and group 3, pQRSd ≥ 190 ms, n = 44. Study outcomes were heart failure events, changes in pQRSd, and changes in left ventricular ejection fraction (LVEF). During the 3-year follow-up, the incidence of heart failure events was 9.4, 27.8, and 56.8% in groups 1, 2, and 3, respectively (P < 0.001). Among the patients without heart failure events, the pQRSd at 3 years remained longer than that at baseline (162.1 ± 22.6 vs. 160.9 ± 22.1 ms, P < 0.05), whereas among patients who experienced heart failure events, the prolonged pQRSd at 3 years seemed more pronounced as compared with baseline (184.1 ± 21.1 vs. 179.8 ± 21 ms, P < 0.001). Linear regression demonstrated that a decrease in LVEF was positively correlated with pQRSd over time (relative risk 0.423; P < 0.05). The receiver operating charactersitic curve showed that the cut-off value of pQRSd was 165 ms with a sensitivity of 0.789. CONCLUSION: A prolonged pQRSd has a detrimental effect on long-term cardiac function during RVAP in patients with complete atrioventricular block. pQRSd could be a useful predictor to identify patients who are at risk for heart failure events during RVAP.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2012) conducted a cohort in Idiopathic complete atrioventricular block (n=194). Prolonged paced QRS duration (pQRSd) vs. pQRSd < 160 ms was evaluated on Heart failure events (p=< 0.001). Prolonged paced QRS duration during right ventricular apical pacing was associated with increased 3-year heart failure events (9.4% for <160 ms, 27.8% for 160-189 ms, and 56.8% for ≥190 ms; P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: