Key result
Greater pacing-induced QRS duration variation in lead V6 was an independent risk factor for atrial fibrillation occurrence (HR 1.822 per 40 ms increase; 95% CI 1.174-2.718; P=0.005).
Why the study?
Does greater paced QRS duration variation increase the risk of atrial fibrillation in patients undergoing permanent pacemaker implantation for atrioventricular block?
Cohort (n=180)
Does greater paced QRS duration variation increase the risk of atrial fibrillation in patients undergoing permanent pacemaker implantation for atrioventricular block?
Greater variation in QRS duration in lead V6 after right ventricular septal pacing is an independent predictor of incident atrial fibrillation, suggesting that minimizing QRS prolongation may be a useful criterion for optimizing pacing sites.
Greater paced QRSd variation in V6 associated with incident AF; leaves open whether minimizing variation reduces risk.
Right ventricular pacing often results in prolonged QRS duration (QRSd) as the result of right ventricular stimulation, and atrial fibrillation (AF) may result. The association of pacing-induced prolonged QRSd and AF in patients with permanent pacemakers is unknown.We selected 180 consecutive patients who underwent pacemaker implantation for complete/advanced atrioventricular block. All of the patients were paced from the right ventricular septum. Electrocardiography recordings were obtained at the beginning and the end of pacemaker implantation. QRSd was measured in all 12 leads. The QRSd variation was calculated by subtracting the preimplantation QRSd from the postimplantation QRSd.The occurrence of AF was observed in 64 (35.56%) patients (follow-up 33.62 ± 21.47 mo). No significant differences in preimplantation QRSd were observed between the AF occurrence and nonoccurrence groups. The QRSd variation in leads V4 (54.22 ± 29.03 vs 42.66 ± 33.79 ms, P = .022), and V6 (64.62 ± 23.16 vs 48.45 ± 34.40 ms, P = .001) differed significantly between the occurrence and nonoccurrence groups. More QRSd variation in lead V6 (P = .005, HR = 1.822, 95% CI 1.174-2.718, interval scale of QRSd was 40 ms) and left atrial diameter (P = .045, HR = 1.042, 95% CI 1.001-1.086) were independent risk factors for AF occurrence. Receiver operating characteristic curve suggested that QRSd variation in lead V6 could predict AF occurrence, especially for patients with long preimplantation QRSd (≥120 ms, area under the curve was 0.826, 95% CI 0.685-0.967).QRSd variation in lead V6 might be positively correlated with postimplantation AF occurrence. In patients with pacemaker implantation, QRSd could be a complementary criterion for optimizing the right ventricular septal pacing site, and smallest QRSd might be worth pursuing.
No takes yet. Share an insight, caveat, or question.
Jiang et al. (2018) conducted a cohort in Complete/advanced atrioventricular block requiring permanent pacemaker (n=180). Pacing-induced QRS duration variation in lead V6 was evaluated on Atrial fibrillation occurrence (HR 1.822, 95% CI 1.174-2.718, p=0.005). Greater pacing-induced QRS duration variation in lead V6 was an independent risk factor for atrial fibrillation occurrence (HR 1.822 per 40 ms increase; 95% CI 1.174-2.718; P=0.005).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: