Why the study?
Does balloon valvuloplasty improve left ventricular compliance in patients with mitral stenosis?
Does balloon valvuloplasty improve left ventricular compliance in patients with mitral stenosis?
Balloon valvuloplasty acutely reverses the impaired left ventricular diastolic compliance seen in patients with mitral stenosis, suggesting the impairment is due to functional restriction by the thickened valve apparatus.
Answers are grounded in this paper and cite their sources.
Balloon valvuloplasty may improve LV compliance in mitral stenosis; hypothesis-generating and requires prospective confirmation before practice change.
BACKGROUND: The mechanisms of depressed left ventricular (LV) pump performance in human mitral stenosis (MS) remain poorly understood, because reduced filling alone affects many hemodynamic measurements. Therefore, pressure-volume relations were examined in nine subjects with MS and compared with eight age-matched normal controls. METHODS AND RESULTS: Data were obtained by conductance catheter/micromanometer technique with transient inferior vena cava occlusion used to alter load and generate pressure-volume relations. In a subset of patients (n = 5), data were obtained both acutely and at 3 months (n = 4) after balloon valvuloplasty. MS patients had reduced cardiac output (3.3 +/- 0.9 versus 5.6 +/- 1.7 l/min) and end-diastolic volume (68.0 +/- 6.9 versus 115 +/- 31 ml) versus controls (p less than 0.001), with a mean transvalvular gradient of 14 +/- 6 mm Hg and estimated valve area of 0.6 +/- 0.2 cm2. Systolic function as assessed by the end-systolic pressure-volume relation was virtually the same in MS and control subjects. In contrast, end-diastolic pressure-volume relations in MS were consistently shifted leftward and had an increased slope (lower compliance) at matched pressure ranges (6.5 +/- 3.0 versus 2.2 +/- 0.53 ml/mm Hg at a mean diastolic pressure of 8 mm Hg, p less than 0.001). This change was not a result of reduced LV filling or probably of increased right heart loading. Valvuloplasty acutely returned chamber compliance to near normal, a change that was sustained at 3-month follow-up. Systolic function was little altered at this time. CONCLUSIONS: These data indicate an impairment of diastolic function in human MS that can be acutely reversed by balloon valvuloplasty. Lowered LV compliance probably results from a functional restriction caused by ventricular attachment to a thickened and immobile valve apparatus.
No takes yet. Share an insight, caveat, or question.
Liu et al. (1992) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: