Consistency monitoring is essential for safe battery energy storage system operation, yet practical data often exhibit asynchronous sampling. This study proposes a tick-driven multi-scale consistency analysis and unsupervised detection method for energy storage batteries. Actual cell-voltage update instants are used as analysis ticks, while high-frequency string-level variables are aggregated over adjacent tick intervals to describe operating conditions. Voltage-dispersion features are then used for anomaly scoring and cell-level localization. The method was evaluated using two-day station data and a controlled 20 Ah 16-series module experiment. In the station dataset, 190 effective ticks were extracted, and a transient consistency deterioration at 24,023 s showed a voltage range of 0.049 V and a standard deviation of 0.0057 V. In the controlled experiment, 185 ticks were obtained from 166,797 voltage samples after 900 s batch resampling, reducing cell-level evaluation instances by over 99%; cell #13 was identified as the dominant high-response cell. The method provides an interpretable framework for consistency monitoring and abnormal-cell localization under asynchronous sampling.