Answers are grounded in this paper and cite their sources.
The performance of a parabolic trough collector (PTC) manufactured in Merida, Yucatán, was evaluated under the ANSI/ASHRAE 93-1986 standard. The water heating system for testing with a constant flow limited to a maximum temperature of 55 °C was built; thus the tests were at low temperatures. Using water as working fluid, it was found that the maximum efficiency of the collector was 5.43%, with a flow rate of 0.022 kg/s at a direct solar irradiance with incidence angle 0°. The evaluation methodology and design of the system for testing the collector is reported in this paper.
No takes yet. Share an insight, caveat, or question.
Hau et al. (2011) studied this question.