Why the study?
To test whether in-stent yellow plaque assessed by angioscopy poses a risk of very late stent failure in CoCr-EES compared with first-generation DES.
Does the presence of in-stent yellow plaque on angioscopy at 1 year predict very late stent failure differently between CoCr-EES and first-generation DES in patients undergoing PCI?
Does the presence of in-stent yellow plaque on angioscopy at 1 year predict very late stent failure differently between CoCr-EES and first-generation DES in patients undergoing PCI?
In-stent atherosclerosis identified as yellow plaque on angioscopy at 1 year is less frequent and has less impact on late clinical events in second-generation CoCr-EES compared to first-generation DES.
Answers are grounded in this paper and cite their sources.
Yellow plaque at 1 year predicts VLSF after first-generation DES but not CoCr-EES; leaves open angioscopy's role in contemporary stent risk stratification.
AIMS: We aimed to test the hypothesis that the presence of in-stent yellow plaque (YP) assessed by angioscopy would be a risk of very late stent failure (VLSF) of the cobalt-chromium everolimus-eluting stent (CoCr-EES) in comparison with first-generation drug-eluting stents (DES). METHODS AND RESULTS: DESNOTE-X was a prospective cohort study, an extended study of the DESNOTE study (UMIN000013515). All patients who received successful angioscopic examination at planned one-year follow-up of DES were clinically followed. The primary endpoint was VLSF defined as a composite of cardiac death, target vessel myocardial infarction, and target lesion revascularisation. A total of 504 patients with 549 lesions were enrolled over a period of 12.5 years. At one-year follow-up, the incidence of YP was significantly higher in the first-generation DES than in the CoCr-EES (199/292 [68%] vs 80/257 [31%], p<0.001). Maximum yellow colour grade on coronary angioscopy at one-year follow-up was an independent predictor of future VLSF in the first-generation DES (HR 2.604 [95% CI: 1.265-5.361], p=0.009), whereas it was not in the CoCr-EES (p for interaction 0.022). CONCLUSIONS: The incidence of in-stent atherosclerosis identified as YP on angioscopy was lower and its impact on late clinical events appeared smaller in the CoCr-EES than in the first-generation DES.
No takes yet. Share an insight, caveat, or question.
Sotomi et al. (2019) studied this question.