Does a multipolar, duty-cycled, bipolar-unipolar RF generator improve procedural efficiency compared to conventional RF ablation in patients with typical atrial flutter?
Does a multipolar, duty-cycled, bipolar-unipolar RF generator improve procedural efficiency compared to conventional RF ablation in patients with typical atrial flutter?
A multipolar, duty-cycled RF ablation system improves procedural efficiency and reduces radiation exposure compared to conventional RF for typical atrial flutter ablation.
Supports multipolar duty-cycled RF for typical atrial flutter ablation; extends RCT evidence of improved procedural efficiency.
INTRODUCTION: Radiofrequency (RF) catheter ablation has been established as an effective and curative treatment for atrial flutter (AFL). Approved methods include a drag-and-drop method, as well as a point-by-point ablation technique. The aim of this study was to compare the acute efficacy and procedural efficiency of a multipolar linear ablation catheter with simultaneous energy delivery to multiple catheter electrodes against conventional RF for treatment of AFL. METHODS: Patients presenting to our department with symptomatic, typical AFL were enrolled consecutively and randomized to conventional RF ablation with an 8-mm tip catheter (ConvRF) or a duty-cycled, bipolar-unipolar RF generator delivering power to a hexapolar tip-versatile ablation catheter (T-VAC) group. For both groups, the procedural endpoint was bidirectional cavotricuspid isthmus block. RESULTS: Sixty patients were enrolled, 30 patients each assigned to ConvRF and T-VAC groups. Total procedure time (40.2 ± 15.8 min vs 60.5 ± 12.7 min), energy delivery time (8.5 ± 3.7 min vs 14.7 ± 5.2 min), radiation dose (14.5 ± 3.5 cGy/cm² vs 31.7 ± 12.1 cGy/cm²), and the minimum number of RF applications needed to achieve block (4.2 ± 2.4 vs 8.9 ± 7.2) were significantly lower in the T-VAC group. In 7 patients treated with the T-VAC catheter, bidirectional block was achieved with less than 3 RF applications, versus no patients with conventional RF energy delivery. CONCLUSION: The treatment of typical AFL using a hexapolar catheter with a multipolar, duty-cycled, bipolar-unipolar RF generator offers comparable effectiveness relative to conventional RF while providing improved procedural efficiency.
No takes yet. Share an insight, caveat, or question.
Erdoğan et al. (2010) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: