Key result
Local threshold-based segmentation of eXIA 160-enhanced micro-CT images generated more accurate vessel geometry than global thresholding, underestimating cast dimensions by.
A novel local threshold-based segmentation protocol using eXIA 160 contrast-enhanced micro-CT enables accurate 3D vessel geometry reconstruction and wall shear stress computation in atherosclerotic mouse models.
Answers are grounded in this paper and cite their sources.
Local thresholding may improve preclinical micro-CT vessel accuracy; leaves open clinical translation pending validation.
BACKGROUND: Wall shear stress (WSS) is involved in the pathophysiology of atherosclerosis. The correlation between WSS and atherosclerosis can be investigated over time using a WSS-manipulated atherosclerotic mouse model. To determine WSS in vivo, detailed 3D geometry of the vessel network is required. However, a protocol to reconstruct 3D murine vasculature using this animal model is lacking. In this project, we evaluated the adequacy of eXIA 160, a small animal contrast agent, for assessing murine vascular network on micro-CT. Also, a protocol was established for vessel geometry segmentation and WSS analysis. METHODS: mice (n = 8). Contrast-enhanced micro-CT was performed using eXIA 160. An innovative local threshold-based segmentation procedure was implemented to reconstruct 3D geometry of the RCCA. The reconstructed RCCA was compared to the vessel geometry using a global threshold-based segmentation method. Computational fluid dynamics was applied to compute the velocity field and WSS distribution along the RCCA. RESULTS: eXIA 160-enhanced micro-CT allowed clear visualization and assessment of the RCCA in all eight animals. No adverse biological effects were observed from the use of eXIA 160. Segmentation using local threshold values generated more accurate RCCA geometry than the global threshold-based approach. Mouse-specific velocity data and the RCCA geometry generated 3D WSS maps with high resolution, enabling quantitative analysis of WSS. In all animals, we observed low WSS upstream of the cast. Downstream of the cast, asymmetric WSS patterns were revealed with variation in size and location between animals. CONCLUSIONS: eXIA 160 provided good contrast to reconstruct 3D vessel geometry and determine WSS patterns in the RCCA of the atherosclerotic mouse model. We established a novel local threshold-based segmentation protocol for RCCA reconstruction and WSS computation. The observed differences between animals indicate the necessity to use mouse-specific data for WSS analysis. For our future work, our protocol makes it possible to study in vivo WSS longitudinally over a growing plaque.
No takes yet. Share an insight, caveat, or question.
Xing et al. (2016) studied Atherosclerosis (n=8). eXIA 160 contrast-enhanced micro-CT with local threshold-based segmentation vs. Global threshold-based segmentation was evaluated on Underestimation of lumen dimension compared to known cast dimension (p=<0.05). Local threshold-based segmentation of eXIA 160-enhanced micro-CT images generated more accurate vessel geometry than global thresholding, underestimating cast dimensions by.
Synapse has enriched 10 related papers. Consider them for comparative context: