Key result
Following HeartMate II LVAD implantation, early improvements in glomerular filtration rate were not sustained, declining to 63.9 at 1 year (p<0.0001 vs 1 and 3 months).
Why the study?
Does HeartMate II LVAD implantation lead to sustained improvements in renal function at 1 year?
Cohort (n=62)
Does HeartMate II LVAD implantation lead to sustained improvements in renal function at 1 year?
p-value: p=<0.0001
Early improvements in renal function following LVAD implantation are often not sustained at 1 year, with shorter bypass time and higher albumin associated with less decline.
Early GFR gains after HeartMate II LVAD may not persist; leaves open need for prospective renal outcome trials.
Renal function improves early after left ventricular assist device (LVAD) implantation but later decline has been observed. We sought to determine the occurrence and evaluate possible causes for this decline. In 62 consecutive patients with HeartMateII LVAD with available calculated glomerular filtration rate (GFR, ml/min/1.73 m) 1 year after implant, GFR was assessed repeatedly and possible predictors for decline from 3 to 12 months were investigated. Post-mortem renal specimens for patients supported with an LVAD were evaluated. GFR 54.5 ± 19.5 at admission increased to 66.4 ± 22.3 preoperatively and to 79.2 ± 30.1 ~1 month after implantation. Subsequently at ~3 months GFR declined to 74.7 ± 25.4, at ~6 months to 68.8 ± 23.1, and ~1 year after implant to 63.9 ± 17.7. Glomerular filtration rate at 1 year was significantly lower (p < 0.0001, p < 0.0001, p = 0.005) than GFR 1, 3, and 6 months after implant. Early rise in GFR after surgery was not associated with late decline. Shorter bypass time (β = -0.09, p = 0.048) and higher albumin 3 months after LVAD (β = 14.4, p = 0.025) were significantly associated with less later decline in GFR. Arteriosclerosis was identified in autopsy renal specimens. In conclusion, early gains in renal function after LVAD implant are not sustained in many patients. Patient, device, and operative factors may influence long-term renal function in these patients.
No takes yet. Share an insight, caveat, or question.
Hasin et al. (2017) conducted a cohort in Heart failure requiring LVAD (n=62). HeartMate II LVAD implantation was evaluated on Glomerular filtration rate (GFR) at 1 year compared to 1, 3, and 6 months post-implant (p=<0.0001). Following HeartMate II LVAD implantation, early improvements in glomerular filtration rate were not sustained, declining to 63.9 at 1 year (p<0.0001 vs 1 and 3 months).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: