Key result
The prospectively self-gated CINE sequence successfully detected 100% of the cardiac triggers and provided excellent CINE image quality without using ECG signals.
Why the study?
Does a prospective cardiac motion self-gating method provide accurate cardiac triggers and comparable image quality to ECG-gating in healthy subjects undergoing cardiac MRI?
Does a prospective cardiac motion self-gating method provide accurate cardiac triggers and comparable image quality to ECG-gating in healthy subjects undergoing cardiac MRI?
A novel prospective cardiac motion self-gating method provides robust and accurate cardiac triggers, offering a viable alternative to conventional ECG-gating for cardiac MRI applications.
Answers are grounded in this paper and cite their sources.
Supports ECG-free cardiac CINE MRI feasibility; leaves open prospective validation before clinical adoption.
BACKGROUND: To develop a prospective cardiac motion self-gating method that provides robust and accurate cardiac triggers in real time. METHODS: The proposed self-gating method consists of an "imaging mode" that acquires the k-space segments and a "self-gating mode" that captures the cardiac motion by repeatedly sampling the k-space centerline. A training based principal component analysis algorithm is utilized to process the self-gating data where the projection onto the first principal component was used as the self-gating signal. Retrospective studies using a sequence with self-gating mode only was performed on 8 healthy subjects to validate the accuracy and reliability of the self-gating triggers. Prospective studies using both ECG-gated and self-gated cardiac CINE sequences were conducted on 6 healthy subjects to compare the image quality. RESULTS: Using the ECG as the reference, the proposed method was able to detect self-gating triggers within ±10 ms accuracy on all 8 subjects in the retrospective study. The prospectively self-gated CINE sequence successfully detected 100% of the cardiac triggers and provided excellent CINE image quality without using ECG signals. CONCLUSIONS: The proposed cardiac self-gating method is a robust and accurate alternative to conventional ECG-based gating method for a number of cardiac MRI applications.
No takes yet. Share an insight, caveat, or question.
Han et al. (2017) studied Healthy volunteers (n=14). Prospective cardiac motion self-gating vs. Conventional ECG-based gating was evaluated on Detection rate of cardiac triggers. The prospectively self-gated CINE sequence successfully detected 100% of the cardiac triggers and provided excellent CINE image quality without using ECG signals.
Synapse has enriched 10 related papers. Consider them for comparative context: