Key result
Three-dimensional transesophageal echocardiography vena contracta area measurement successfully quantified severe degenerative mitral regurgitation with multiple jets, yielding a summed area of 0.68 cm2.
Why the study?
Does 3D vena contracta area measurement improve the quantification of degenerative mitral regurgitation with multiple jets in atrial fibrillation compared to 2D PISA?
Case Report (n=1)
No
Does 3D vena contracta area measurement improve the quantification of degenerative mitral regurgitation with multiple jets in atrial fibrillation compared to 2D PISA?
Answers are grounded in this paper and cite their sources.
3D vena contracta area measurement by TEE provides a more accurate quantification of degenerative mitral regurgitation severity in patients with multiple jets and atrial fibrillation compared to 2D PISA.
Quantification of degenerative mitral regurgitation with multiple jets in atrial fibrillation is challenging with two dimensional techniques and may underestimate the severity. We report the feasibility and advantages of vena contracta area in three dimensional transesophageal echocardiography in evaluation of such a patient.
No takes yet. Share an insight, caveat, or question.
Ching et al. (2022) conducted a case report in Degenerative mitral regurgitation with multiple jets and atrial fibrillation (n=1). 3D transesophageal echocardiography vena contracta area measurement vs. 2D PISA was evaluated on Quantification of mitral regurgitation severity. Three-dimensional transesophageal echocardiography vena contracta area measurement successfully quantified severe degenerative mitral regurgitation with multiple jets, yielding a summed area of 0.68 cm2.