Key result
Telemedical home blood pressure was lower than daytime ambulatory blood pressure, though the two were strongly correlated.
Why the study?
How does telemedical home blood pressure compare to office and ambulatory blood pressure monitoring in renal outpatients?
Cross-Sectional (n=102)
No
How does telemedical home blood pressure compare to office and ambulatory blood pressure monitoring in renal outpatients?
Telemedical home blood pressure monitoring yields slightly lower readings than daytime ambulatory monitoring but correlates strongly and is well accepted by patients.
Answers are grounded in this paper and cite their sources.
Telemedical home BP should not yet replace ambulatory monitoring in renal outpatients; leaves open its role pending outcome validation.
Background: Telemonitoring of home blood pressure (HBP) is a new advance in blood pressure monitoring. The aim of this study was to compare office blood pressure (OBP) and telemedical home blood pressure with daytime ambulatory blood pressure (ABP). Methods: One hundred and two patients were recruited consecutively from our Renal Outpatients’ Clinic. Office blood pressure was measured three times with the HBP equipment (A&D UA-767Plus BT). Telemonitoring of HBP was done for four consecutive days with three measurements three times daily followed by ABP (A&D TM-2430) on the next day. All patients received a questionnaire regarding acceptance of the equipment. Results: OBP was a significantly higher than daytime ABP (systolic/diastolic, 3.3/3.8 mmHg). HBP was significantly lower than daytime ABP (systolic/diastolic, -4.6/-1.6 mmHg). The strongest correlations were seen between all HBP readings day 2-4 and daytime ABP (systolic, r=0.69, p<0.001; diastolic, r=0.61, p<0.001). There were no significant differences between the different HBP schedules, i.e. 3 measurements twice daily for 3 days and 3 measurements three times daily for 4 days. Patients were content with and accepted the HBP measuring device. Conclusion: The telemedical HBP was lower than daytime ABP. The observed difference could possible be due to less pain and more relaxation during HBP measurements or a systematic difference in the algoritms between the blood pressure measuring devices. HBP measurement during three days was as good as measurement during 4 days.. The equipment was well accepted among patients.
No takes yet. Share an insight, caveat, or question.
Hoffmann-Petersen et al. (2015) conducted a cross-sectional in Renal outpatients (n=102). Telemedical home blood pressure (HBP) monitoring vs. Daytime ambulatory blood pressure (ABP) was evaluated on Difference between HBP and daytime ABP (MD -4.6/-1.6 mmHg (systolic/diastolic)). Telemedical home blood pressure was lower than daytime ambulatory blood pressure, though the two were strongly correlated.