Why the study?
Does telemedical home blood pressure measurement improve the prediction of daytime ambulatory blood pressure compared to clinic blood pressure in patients with elevated clinic blood pressure?
Does telemedical home blood pressure measurement improve the prediction of daytime ambulatory blood pressure compared to clinic blood pressure in patients with elevated clinic blood pressure?
Telemedical home blood pressure measurement is significantly more accurate than clinic blood pressure in predicting daytime ambulatory blood pressure, with optimal accuracy achieved after four days of monitoring.
Answers are grounded in this paper and cite their sources.
Telemedical HBP may better estimate ABP than CBP; leaves open whether it should replace clinic readings before outcome trials.
The purposes of this study were to determine the accuracy of clinic blood pressure (CBP) and telemedical home blood pressure (HBP) measurement in predicting daytime ambulatory blood pressure (ABP), and to assess whether the time of day has any influence on the reliability of HBP in diagnostic decisions. 411 patients with average CBP≥ 140 mmHg systolic or≥ 90 mmHg diastolic performed telemedical HBP measurement (five days, four times daily, duplicate measurements) and ABP in random order. CBP (164.3 ± 19.3/97.5 ± 9.8 mmHg) was much higher than average HBP (152.2 ± 15.6/90.6 ± 9.0 mmHg) and daytime ABP (152.1 ± 15.0/89.8 ± 10.6 mmHg) (P < 0.001), with no difference between the two latter. There was a progressive decline in HBP over the five monitoring days; systolic and diastolic pressure on each day being significantly lower than the pressure on the preceeding day (P < 0.05). We observed a weak linear correlation between CBP and ABP (r = 0.499/0.543 for systolic/diastolic BP), whereas the correlation between HBP and ABP was substantially stronger (r = 0.847/0.812) (P < 0.001). A progressive improvement in the strength of the linear regression between average HBP of single days and ABP was obtained from day 1 to 4, with no further benefit obtained on the fifth day. The HBP readings taken at noon (11 AM - 2 PM) and in the afternoon (4 PM - 7 PM) showed a stronger correlation with ABP than the values obtained in the morning (6 AM - 9 AM) and evening (10 PM - midnight) (P < 0.05). Averaging increasing numbers of HBP readings obtained on succeeding days resulted in a progressive improvement in the strength of the relationship between HBP and ABP. The majority of the strength in this correlation between home and ambulatory readings was achieved on the first four days with only very little further improvement, when readings from the last day were incorporated. The exclusion of HBP readings of the initial day offered no advantage. These results suggest that the accuracy of telemedical HBP measurement is substantially better than that of the conventional BP measurement in the clinic in diagnostic decisions. HBP most accurately reflected ABP on the fourth day of monitoring with no further improvement on the fifth day. Furthermore, the accuracy of HBP varied according to the time of day with the pressures measured at noon and in the afternoon being superior to those taken in the morning and evening.
No takes yet. Share an insight, caveat, or question.
David R. Möller (2003) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: