Key result
An electronic reminder and monitoring device improved self-reported compliance to 91% compared to 85% with standard therapy in the first 6 months, but did not affect blood pressure.
Why the study?
Does an electronic reminder and monitoring device improve patient compliance and blood pressure control in hypertensive patients?
RCT (n=398)
randomized
Does an electronic reminder and monitoring device improve patient compliance and blood pressure control in hypertensive patients?
Answers are grounded in this paper and cite their sources.
An electronic reminder device modestly improves self-reported compliance in hypertensive patients but does not significantly affect blood pressure control when used with forgiving medications like telmisartan.
BACKGROUND: High blood pressure (BP) significantly increases overall cardiovascular risk, the incidence of ischemic heart disease and stroke. One of the most important causes of insufficient BP control is low treatment compliance. Reminders and electronic compliance monitoring have been shown to be effective in improving patient compliance to some extent, but the combined effect has not been documented. OBJECTIVE: To assess the impact of an electronic reminder and monitoring device on patient compliance and BP control. METHODS: All patients received medical treatment with telmisartan once daily and were randomized to either electronic compliance monitoring with a reminder and monitoring device or standard therapy for 6 months. Both groups were crossed over after 6 months. Intervention effectiveness was assessed using self-reported compliance and BP. RESULTS: Data from 398 patients were analysed. In the first half of the study, patients using the device reported 91% compliance versus 85% in the control group. This difference diminished after crossover (88 versus 86%). BP was not affected. Electronic monitoring data on compliance revealed taking, dosing and timing compliance between 45 and 52% in study group 1, and between 32 and 38% in study group 2. CONCLUSION: The Helping Hand reminder device was most suitable if used for newly diagnosed hypertensive patients, when it improved compliance by 6%. With the present medical treatment, the device does not have any influence on BP control, but with less forgiving medications, the device might make a significant difference. The use of the device can be an easy and effective way to improve compliance in selected patients.
No takes yet. Share an insight, caveat, or question.
Christensen et al. (2009) conducted an RCT in High blood pressure (n=398). electronic compliance monitoring with a reminder and monitoring device vs. standard therapy was evaluated on self-reported compliance. An electronic reminder and monitoring device improved self-reported compliance to 91% compared to 85% with standard therapy in the first 6 months, but did not affect blood pressure.