Key result
Lead aVR ST elevation linked to ~3.3-fold higher PE mortality, losing significance after adjusting for shock.
Why the study?
Prognostic stratification of patients with acute pulmonary embolism is crucial for identifying those who would benefit from more aggressive treatment, prompting an evaluation of ST elevation in lead aVR as a predictor of hospital mortality.
Does ST elevation in lead aVR predict hospital mortality in patients with acute pulmonary embolism?
Cohort (n=200)
No
Does ST elevation in lead aVR predict hospital mortality in patients with acute pulmonary embolism?
Answers are grounded in this paper and cite their sources.
ST elevation in lead aVR indicates hemodynamic instability in acute pulmonary embolism but is not an independent predictor of hospital mortality when accounting for clinical shock.
Prognostic stratification of patients with acute pulmonary embolism (PTE) is crucial in identifying patients who would benefit from more aggressive treatment. We aimed to examine the value of ST elevation in lead aVR (STE aVR ) in predicting hospital mortality following PTE. Two hundred patients with a diagnosis of PTE were allocated into two groups based on the presence or absence of STE aVR . Multivariate logistic regression analysis was used to investigate the role of “STE aVR ” in relation to the other risk factors in predicting prognosis of PTE. Out of 200 patients, 24 (12.0%) had STE aVR . Patients with STE aVR were more likely to present with hypotension and tachycardia than those who did not have this electrocardiographic finding. A total of 33.3% of patients with STE aVR and 13.1% of those without STE aVR died during hospitalization. STE aVR had a low sensitivity of 25.8% but a high specificity of 90.5% for predicting hospital mortality. Odds ratio for hospital mortality was 3.32 for STE aVR with 95% confidence interval of 1.28–8.64 (P = 0.017) in univariate analysis. In multivariate analysis shock was the strongest predictor of hospital mortality. The presence of STE aVR is indicative of hemodynamic instability, thereby having the ability to predict poor outcome. However, its impact on hospital mortality disappears when the presence of shock on admission is factored in the prediction model.
No takes yet. Share an insight, caveat, or question.
Pourafkari et al. (2016) conducted a cohort in Acute pulmonary embolism (n=200). ST segment elevation in lead aVR (STEaVR >=1 mm on admission ECG) vs. Absence of ST segment elevation in lead aVR was evaluated on Hospital mortality (OR 3.32, 95% CI 1.28-8.64, p=0.017). ST elevation in lead aVR was associated with increased hospital mortality in acute pulmonary embolism in univariate analysis, but not after adjusting for shock.