Infection of cardiac implantable electronic devices is a significant public health problem, requiring evaluation of diagnostic tools.
Does 18F-FDG PET/CT accurately diagnose infection in patients suspected of Cardiac Implantable Electronic Devices' Infection?
Does 18F-FDG PET/CT accurately diagnose infection in patients suspected of Cardiac Implantable Electronic Devices' Infection?
18F-FDG PET/CT demonstrates high sensitivity and diagnostic accuracy for evaluating suspected cardiac implantable electronic device infections.
Background: Infection of Cardiac Implantable Electronic Devices (CIEDI) is a real public health problem. The main aim of this study was to determine the diagnostic performance of 18F-FDG PET/CT in the diagnosis of CIEDI. Methods: A total of 48 patients, who performed 18F-FDG PET/CT for the clinical suspicion of CIEDI were retrospectively analyzed; all patients were provided with a model with procedural recommendations before the exam. Sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy (DA) of 18F-FDG PET/CT were calculated; the reproducibility of qualitative analysis was assessed with Cohen’s κ test. The semi-quantitative parameters (SUVmax, SQR and TBR) were evaluated in CIEDI+ and CIEDI− patients using the Student’ t-test; ROC curves were elaborated to detect cut-off values. The trend of image quality with regards to procedural recommendation adherence was evaluated. Results: Se, Sp, PPV, NPV and DA were respectively 96.2%, 81.8%, 86.2%, 94.7% and 89.6%. The reproducibility of qualitative analysis was excellent (K = 0.89). Semiquantitative parameters resulted statistically different in CIEDI+ and CIEDI− patients. Cut-off values were SUVmax = 2.625, SQR = 3.766 and TBR = 1.29. Trend curves showed increasing image quality due to adherence to procedural recommendations. Conclusions: 18F-FDG-PET/CT is a valid tool in the management of patients suspected of CIEDI and adherence to procedural recommendations improves its image quality.
No takes yet. Share an insight, caveat, or question.
Pisani et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: