Key result
18F-FDG PET/CT imaging demonstrated high diagnostic accuracy for early identification of confirmed CIED generator pocket infection requiring extraction.
Why the study?
Does 18F-FDG PET/CT imaging accurately diagnose early cardiac implantable electronic device generator pocket infection in patients with CIEDs?
Observational (n=86)
Does 18F-FDG PET/CT imaging accurately diagnose early cardiac implantable electronic device generator pocket infection in patients with CIEDs?
18F-FDG PET/CT provides high diagnostic accuracy for the early detection of CIED generator pocket infections, potentially guiding extraction decisions even when clinical signs are subtle.
Answers are grounded in this paper and cite their sources.
May aid early CIED pocket infection detection when signs are subtle; leaves open prospective validation before routine adoption.
AIMS: To examine the utility of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) in the early diagnosis of cardiac implantable electronic device (CIED) generator pocket infection. METHODS AND RESULTS: A total of 86 patients with CIEDs were evaluated with (18)F-FDG PET/CT imaging: 46 with suspected generator pocket infection and 40 without any history of infection. (18)F-FDG activity in the region of the generator pocket was expressed as a semi-quantitative ratio (SQR)-defined as the maximum count rate around the CIED divided by the mean count rate between normal right and left lung parenchyma. All patients underwent standard clinical management, independent of the PET/CT result. Patients with suspected generator pocket infection that required CIED extraction (n = 32) had significantly higher (18)F-FDG activity compared with those that did not (n = 14), and compared with controls (n = 40) [SQR: 4.80 (3.18-7.05) vs. 1.40 (0.88-1.73) vs. 1.10 (0.98-1.40), respectively; P < 0.001]. On receiver operator characteristic analysis, SQR had a high diagnostic accuracy (area under curve = 0.98) for the early identification of patients with confirmed infection (i.e. those ultimately needing extraction)-with an optimal SQR cut-off value of >2.0 (sensitivity = 97%; specificity = 98%). CONCLUSION: This study highlights the potential benefits of evaluating patients with suspected CIED generator pocket infection using (18)F-FDG PET/CT. In this study, (18)F-FDG PET/CT had a high diagnostic accuracy in the early diagnosis of CIED generator pocket infection, even where initial clinical signs were underwhelming.
No takes yet. Share an insight, caveat, or question.
Ahmed et al. (2015) conducted an observational in Suspected cardiac implantable electronic device (CIED) generator pocket infection (n=86). 18F-FDG PET/CT imaging vs. Patients without confirmed infection or controls was evaluated on Confirmed CIED generator pocket infection requiring extraction (AUC 0.98, p=<0.001). 18F-FDG PET/CT imaging demonstrated high diagnostic accuracy for early identification of confirmed CIED generator pocket infection requiring extraction.