Key result
18F-FDG PET/CT scan successfully established the diagnosis of CIED infection localized to the vascular ICD lead and generator-pocket after several negative transesophageal echocardiography studies.
Why the study?
Does 18F-FDG PET/CT improve the diagnosis of CIED infection in patients with negative TEE?
Case Report (n=1)
No
Does 18F-FDG PET/CT improve the diagnosis of CIED infection in patients with negative TEE?
18F-FDG PET/CT can successfully identify CIED infections in patients with persistent bacteremia when standard TEE imaging is negative.
May support 18F-FDG PET/CT for CIED infection diagnosis after negative TEE; leaves open need for prospective validation before practice change.
Introduction: In the last decade, there has been an accelerated increase in the number of cardiovascular implantable electronic device (CIED) implantations. Similarly, CIED infections have risen significantly with a three-fold augmentation for pacemaker infections and a six-fold augmentation for implantable cardioverter defibrillator (ICD) infections. The complications of CIED infections may be critical, and related infections are associated with heightened risk of mortality. Most patients, who experience symptoms related to CIED infections present either a generator-pocket site inflammation or unspecific symptoms in relation to positive blood cultures or fever of unknown origin. The diagnosis is mainly supported by evidence of cardiac or CIED involvement by transesophageal echocardiography (TEE). Case Presentation: In this report, we describe a case of a CIED infection in a 49-year-old female, admitted in 2013 to a hospital in Copenhagen, Denmark, with persistent Staphylococcus epidermidis bacteremia without any clinical signs of generator-pocket infection and several negative TEE studies. Conclusions: The diagnosis of CIED infection was established with Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (18F-FDG PET/CT) scan revealing clear evidence of infection localized to the vascular ICD lead and generator-pocket.
No takes yet. Share an insight, caveat, or question.
Lauridsen et al. (2016) conducted a case report in Cardiovascular implantable electronic device (CIED) infection (n=1). 18F-FDG PET/CT scan was evaluated on Diagnosis of CIED infection. 18F-FDG PET/CT scan successfully established the diagnosis of CIED infection localized to the vascular ICD lead and generator-pocket after several negative transesophageal echocardiography studies.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: