Key result
Novel capillary blood VAMS LC-MS method reliably quantifies DOACs and phenprocoumon.
Answers are grounded in this paper and cite their sources.
A novel LC-MS method using volumetric absorptive microsampling was successfully validated for the simultaneous quantification of DOACs and phenprocoumon from capillary blood, facilitating ambulatory therapeutic drug monitoring.
• A method with five anticoagulants for the TDM were developed, including the DOACs. • An on-line SPE system has been used to simplify the extraction. • VAMS® have been used for the ambulatory sector. • With LC-MS a simple and cost-efficient detector has been used. The number of prescriptions for new direct oral anticoagulants (DOACs) apixaban, edoxaban, rivaroxaban and dabigatran has increased exponentially in recent years, increasingly replacing the old gold standard, vitamin-K-antagonists. Due to their wide therapeutic range, therapeutic drug monitoring (TDM) is not required, although it has been proven that this could significantly reduce side effects. In order to develop a cost-efficient and simple method for the simultaneous detection of the DOACs and phenprocoumon, a new technology for sample preparation from capillary blood in the ambulant sector named VAMS® was integrated and an LC-MS detector with on-line solid phase extraction (SPE) applying a Turboflow HTLC Cyclone TM 1.0x50 mm column was used. The mobile phase consisted of methanol with water (3/97 v/v) and 0.1 % ammonia solution with a flow rate of 2.5 mL/min. For the chromatographic separation, a Phenomenex LTD Kinetex 2.6 µm C18 100 Å, 100x3.0 mm column with a flow rate of 0.3 mL/min in gradient mode was utilized. The mobile phase consisted of acetonitrile, water and formic acid (A: 10:90:0.1 v/v and B: 95:05:0.1 v/v). The method was fully validated in the therapeutic range of the substances according to current guidelines. The LLOQ ranged from 3.5 µg/L for rivaroxaban to 88 µg/L for phenprocoumon and the intra-day and inter-day precision was less than 13 % and 12 %, while the accuracy was within a range of 85.7–113 % and 88.7–106 %, respectively. Samples could be stored in the Mitra® devices for at least seven days at room temperature except of dabigatran. Because the Mitras® were used, exactly 10 µL of blood could be drawn and no significant haematocrit effect was observed. A reliable, simple and cost-effective extraction and analysis LC-MS method could be developed and validated. This method is therefore applicable in ambulatory care.
No takes yet. Share an insight, caveat, or question.
Opitz et al. (2024) studied Therapeutic drug monitoring of DOACs and phenprocoumon. VAMS and online SPE-LC-MS was evaluated on Method validation parameters (LLOQ, precision, accuracy). A reliable and cost-effective LC-MS method using VAMS for the simultaneous detection of DOACs and phenprocoumon from capillary blood was successfully developed and validated.
Synapse has enriched 10 related papers. Consider them for comparative context: