Why the study?
Does the BVS 5000 ventricular assist device provide effective short-term mechanical cardiac support as a bridge to recovery or transplant in patients with post-cardiotomy shock and heart failure?
Does the BVS 5000 ventricular assist device provide effective short-term mechanical cardiac support as a bridge to recovery or transplant in patients with post-cardiotomy shock and heart failure?
The BVS 5000 ventricular assist device is an effective short-term mechanical support option for patients with post-cardiotomy shock and heart failure, achieving a 54% transplant or wean rate.
Answers are grounded in this paper and cite their sources.
May support BVS 5000 feasibility in post-cardiotomy shock; hypothesis-generating and requires prospective validation.
The use of mechanical cardiac support has become a routine treatment option in patients suffering from post-cardiotomy shock and heart failure. A five-year experience with the BVS 5000 ventricular assist device in 63 patients is reported. Sixty-three patients, aged 8 to 72 y.o., with the following etiologies were supported: post-cardiotomy (n=34), dilated cardiomyopathy (CM), ischemic CM (n=4), RVAD with Heartmate (n=4), status-post myocardial infarction (n=4), post-partum CM (n=3), RVAD only post-transplant (n=2), acute viral myocarditis (n=2), giant cell myocarditis (n=2), and congenital (n=1). Forty-three were male. Thirty-four patients were transferred into our institution specifically for VAD treatment with 22 already on support. Twenty-nine patients received left-ventricular support only, 12 right ventricular, and 22 biventricular. Average duration of support was 8 days (0–44). Twenty patients were transplanted and 12 were weaned, for an overall transplanted/wean percentage of 54%. Twenty-one survived to hospital discharge. Of those completing a short-term bridge to transplant, 70% were successfully discharged. Average total hospital stay for these patients was 33 days. The BVS 5000 is effective for use in situations where temporary, short-term cardiac support is required. Its simplicity of use and low cost make it ideal for both transplant and non-transplant cardiac surgery centers. It offers the possibility of a bridge to recovery, transplant, or an implantable system.
No takes yet. Share an insight, caveat, or question.
Marelli et al. (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: