Key result
Early insertion of the Abiomed BVS 5000 allowed 64% of patients to be weaned off support and 43% to be discharged, whereas none of the patients with late postoperative implantation could be weaned.
Why the study?
Does the Abiomed BVS 5000 biventricular support system improve survival and weaning rates in patients requiring circulatory support for severe cardiac surgical conditions?
Observational (n=17)
No
Does the Abiomed BVS 5000 biventricular support system improve survival and weaning rates in patients requiring circulatory support for severe cardiac surgical conditions?
The Abiomed BVS 5000 can provide life-saving circulatory support in critical cardiac surgical conditions, with more favorable results achieved when the device is placed early.
Answers are grounded in this paper and cite their sources.
Early Abiomed BVS 5000 insertion may aid weaning in postcardiotomy shock; leaves open prospective confirmation of benefit.
Since 1987 the Abiomed BVS 5000 biventricular support system has been used successfully for circulatory support in a variety of settings. From June 1994 through December 1996, 20 of these devices were implanted in 17 patients at the Allegheny University Hospitals for ventricular support in these circumstances: following coronary artery bypass-grafting; after left ventricular aneurysm repair; after repair of a postinfarction ventricular septal defect; following double valve replacement; as a bridge to transplantation; and for right ventricular support following transplantation in patients with marked pulmonary hypertension. Fourteen devices were placed at the time of the initial cardiac surgery. Three devices were placed postoperatively after the initial cardiotomy. Of the 14 patients with early insertion, 9 (64%) were weaned off support, 8 (57%) died, and 6 (43%) were discharged. The 3 patients who underwent postoperative implantation could not be weaned from the device. This experience indicates that the Abiomed BVS 5000 can be used to preserve life in a variety of cardiac surgical conditions that would otherwise be fatal and more favorable results can be achieved when the device is placed early.
No takes yet. Share an insight, caveat, or question.
Samuels et al. (1997) conducted an observational in Cardiac surgical conditions requiring ventricular support (n=17). Abiomed BVS 5000 biventricular support system (early insertion) vs. Postoperative implantation (late insertion) was evaluated on Weaning off support. Early insertion of the Abiomed BVS 5000 allowed 64% of patients to be weaned off support and 43% to be discharged, whereas none of the patients with late postoperative implantation could be weaned.
Synapse has enriched 10 related papers. Consider them for comparative context: