An optically flat copper laser mirror which is integral to a water heat pipe was designed for ultimate retrofit in an existing CO/sub 2/ laser. It was tested for thermally induced distortions, and an analytical model was developed and compared with experimental deflection results. Thermal tests were performed with a carbon arc solar simulator as a heat source resulting in calorimetrically measured heat fluxes up to 350 W/cm/sup 2/ through the heat pipe. Surface distortion measurements were performed by holographic interferometry with an electron beam for mirror surface heating. A deflection analysis of the particular heat pipe mirror with internal structural ribs behind the mirror face was developed by solving Laplace's equation, and a variational method was used to determine the thermally induced deflections. The mirror face temperature distribution was determined by separation of variables, nondimensional analysis for variable input beam diameter, and energy distribution. The analysis predicts conditions for minimum and maximum deflections. A comparison of thermal deflections from analysis and experiment at 107 W over 2 cm/sup 2/ resulted in a difference of approximately 7% when pressure contributions to the experimental data were removed.