Why the study?
Does electrophysiologic testing accurately identify transient bradyarrhythmias in patients with syncope whose cardiac rhythm has reverted to normal?
Population
21 patients with electrocardiographically documented intermittent atrioventricular block or sinus pauses…
Design
Cohort
Authors
Loading...
Negative electrophysiologic testing does not exclude transient bradyarrhythmia in syncope; leaves open its diagnostic utility.
Does electrophysiologic testing accurately identify transient bradyarrhythmias in patients with syncope whose cardiac rhythm has reverted to normal?
A negative electrophysiologic test does not exclude transient bradyarrhythmia as a cause of syncope in patients with normal baseline rhythm, and may reveal unrelated, potentially misleading rhythm disturbances.
Fujimura et al. (1989) studied this question.