Answers are grounded in this paper and cite their sources.
The enhanced thermal-hydraulic performance of single-phase flows in a plate heat exchanger with mixed chevron plates is investigated experimentally. The mixed arrangement consists of plates with chevron angle β = 30° and 60°, alternatingly stacked in a single-pass, U-type, counterflow configuration. Vegetable oil (130 < Pr < 220) and water (2.4 < Pr < 4.5) are used as test fluids, with flow rates in the laminar, transition, and turbulent flow regimes (2 < Re < 6000). Results for isothermal friction factor and heat transfer under cooling conditions, along with respective correlations for laminar (2 < Re < 400) and fully developed turbulent (Re ≥ 1000) flows are presented; transition is observed to set in when Re ∼ 500. The heat transfer data are obtained from controlled experiments, employing an extension of the Wilson Plot technique. A comparison of the data with previously reported results and predictive equations for Nu and / highlights the latter’s lack of general applicability, and the need for a larger database. The relative impact of using mixed chevron plate arrangement is discussed, and their enhanced performance, in comparison with parallel-plate channels, is evaluated.
No takes yet. Share an insight, caveat, or question.
Muley et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: