REVIOUS studies1'2 have identified MHD channel configurations and operating conditions which result in peak thermodynamic efficiency of the combined MHD/steam plant. A critical factor in these studies was that the MHD channel was cooled by low-pressure, low-temperature boiler feedwater. This results in a lowering of the steam plant efficiency with increasing MHD channel heat loss since it reduces the amount of regenerative boiler feedwater heating that can be done within the steam plant itself. In these initial studies, only the active (significantly power-producing) region of the channel was considered. This region was taken to extend from a 5-field low of 4 T at the front of the channel to a B-field low of approximately 3.5 T at the rear of the channel (see Fig. 1). However, even though the regions upstream and downstream of the active region do not produce significant amounts of power, they still produce significant voltage which requires voltage isolation. Therefore these regions require MHD-channel-type construction and hence cooling with lowpressure, low-temperature boiler feedwater with the attendant possibility of a further reduction in overall plant efficiency. The results presented in this paper apply only to plants of the size of 200 MWe and to MHD channels whose design requirements specify cooling with low-pressure, lowtemperature boiler feedwater. The sensitivity of various channel parameters (maximum B-field, diffuser recovery coefficient, generator load parameter, Mach number, and combustor pressure) are examined under the constraints of a maximum axial electric field (Ex) of 2.5 kV/m, a maximum transverse electric field (Ey) of 4 kV/m, and a maximum transverse current (Jy) of 10 kA/m2. II. Background The channel analysis is based on a quasi-one-dimensional code.3 However, in this study, the code has been modified to allow the calculation of the voltage drops through the integral boundary layer. This is necessary since the original model is inadequate for the channel end regions. In addition to the voltage-drop calculations, the channel code utilizes tabulated chemical equilibrium properties which are computed separately.4 This allows a considerable reduction of the required computing time, especially in the region of the boundary layers. The channel code is then combined with an overall system calculation2 to determine the performance of the MHD/steam plant.
No takes yet. Share an insight, caveat, or question.
Wang et al. (1982) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: