Key result
Continuous-wave Doppler ultrasound monitoring during anthracycline therapy observed a 6.5% decrease in stroke volume over 3 months, comparable to a 2.1% decrease in ejection fraction by echocardiography.
Why the study?
Does continuous wave-Doppler ultrasound cardiac output monitoring combined with serum biomarkers accurately monitor hemodynamic changes compared to echocardiography in cancer patients receiving anthracyclines?
Observational (n=50)
Does continuous wave-Doppler ultrasound cardiac output monitoring combined with serum biomarkers accurately monitor hemodynamic changes compared to echocardiography in cancer patients receiving anthracyclines?
Combining real-time CW-Doppler USCOM and serum biomarkers is feasible for monitoring immediate and chronic hemodynamic changes during anthracycline therapy, yielding results comparable to echocardiography.
Answers are grounded in this paper and cite their sources.
Should not yet change anthracycline monitoring practice; supports further prospective validation of CW-Doppler versus echocardiography.
BACKGROUND: Anthracyclines are agents with a wellknown cardiotoxicity. The study sought to evaluate the hemodynamic response to an anthracycline using realtime continuous-wave (CW)-Doppler ultrasound cardiac output monitoring (USCOM) and echocardiography in combination with serum biomarkers. METHODS: 50 patients (26 male, 24 female, median age 59 years) suffering from various types of cancer received an anthracycline-based regimen. Patients' responses were measured at different time points (T0 prior to infusion, T1 6 h post infusion, T2 after 1 day, T3 after 7 days, and T4 after 3 months) with CW-Doppler ultrasound (T0-T4) and echocardiography (T1, T4) for hemodynamic parameters such as stroke volume (SV; SVUSCOM ml) and ejection fraction (EF; EFechocardiography%) and with NT-pro-BNP and hs-Troponin T (T0-T4). RESULTS: During the 3-month observation period, the relative decrease in the EF determined by echocardiography was -2.1% (▵T0-T4, T0 71 ± 7.8%, T4 69.5 ± 7%, p = 0.04), whereas the decrease in SV observed using CW-Doppler was -6.5% (▵T0-T4, T0 54 ± 19.2 ml, T4 50.5 ± 20.6 ml, p = 0.14). The kinetics for serum biomarkers were inversely correlated. CONCLUSIONS: Combining real-time CW-Doppler USCOM and serum biomarkers is feasible for monitoring the immediate and chronic hemodynamic changes during an anthracycline-based regimen; the results obtained were comparable to those from echocardiography.
No takes yet. Share an insight, caveat, or question.
Geiger et al. (2012) conducted an observational in Cancer (receiving anthracycline-based regimen) (n=50). Continuous-wave (CW)-Doppler ultrasound cardiac output monitoring (USCOM) vs. Echocardiography was evaluated on Relative decrease in ejection fraction (EF) and stroke volume (SV). Continuous-wave Doppler ultrasound monitoring during anthracycline therapy observed a 6.5% decrease in stroke volume over 3 months, comparable to a 2.1% decrease in ejection fraction by echocardiography.
Synapse has enriched 10 related papers. Consider them for comparative context: